Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T07CM03773
Review Name: COMMERCIAL TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/18/2007 | LEERAY HANLY | BUILDING-COMMERCIAL | REVIEW | Denied | 1) THE LAVATORY ENCROACHES ON CLEAR FLOOR SPACE AROUND WATER CLOSET. REFERENCE 2003 ANSI 117.1 SECTION 604.3.2 2) APPROVED APPEAL TO BUILDING OFFICIAL IS REQUIRED TO SUBSTITUTE BOTTLED WATER FOR DRINKING FOUNTAIN. 3) PLEASE INDICATE CORRECT UNISEX ACCESSIBLE SIGNAGE FOR RESTROOM. DETAIL A4/A6.1. |
| 09/18/2007 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Approved | |
| 09/18/2007 | LINDA BUCZYNSKI | ELECTRICAL-COMMERCIAL | REVIEW | Denied | T07CM03773 9/18/07 1. Water Heater is 120V per Sheet P1.1, but electrical provides 208. Coordinate with Plumbing and clarify. |
| 09/18/2007 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 09/18/2007 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Provide a water riser diagram. 2. Show how the temperature of the hot water supply to the public lavatory is controlled. Reference Section 413.1, UPC 2006 and Section 504.3, IECC 2006. 3. Provide listing information to show that the 2-way cleanout shown in Detail C2/P1.1 is not in violation of Section 707.6, UPC 2006. |
| 09/19/2007 | JASON GREEN | ENGINEERING | REVIEW | Approved | |
| 09/19/2007 | HEATHER THRALL | ZONING | REVIEW | Approved | |
| 09/19/2007 | DAVE MANN | FIRE | REVIEW | Approved | |
| 09/28/2007 | DROBEY1 | WWM | REVIEW | Needs Review | |
| 09/28/2007 | BETH GRANT | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Needs Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 09/28/2007 | DELMA ROBEY | APPROVAL SHELF | Completed |
| 09/28/2007 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 09/28/2007 | DELMA ROBEY | REJECT SHELF | Completed |