Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Number: T07CM03655
Parcel: 13355231A

Review Status: Completed

Review Details: COMMERCIAL TI

Permit Number - T07CM03655
Review Name: COMMERCIAL TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/06/2007 DAVE MANN FIRE REVIEW Approved
09/06/2007 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Denied Show that the size of the proposed dryer exhaust duct (clarify the size - 5x3 or 6x3) conforms to the requirements of the dryer manufacturer. Reference Section 504.6, IMC 2006.
09/06/2007 RBROOKS1 ELECTRICAL-COMMERCIAL REVIEW Denied 1. PROVIDE LIGHTING LOAD CALCULATION TO CONFIRM COMPLIANCE WITH THE IECC
09/06/2007 ROBERT SHERRY WATER REVIEW Approved
09/06/2007 RBROOKS1 BUILDING-COMMERCIAL REVIEW Denied 1. PROVIDE ACCESS INTO RESTROOM AS DEFINED BU ANSI A117.1 SECTION 404.2.3

2. PROVIDE ACCESS TO THE WASHER AND DRYER AS SPECIFIED BY ANSI A117.1 SECTION 611 AND 305
09/06/2007 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied 1. Provide access to the cleanout currently located behind the water heater.
2. Provide a detail of the water heater installation, including the excess pressure relief, expansion tank, and valves. Reference Sections 103.2.3, 605.5, and 608.7 UPC 2006.
09/12/2007 GBONILL1 WWM REVIEW Needs Review
09/12/2007 GBONILL1 ZONING REVIEW Needs Review
09/12/2007 GBONILL1 ENGINEERING REVIEW Needs Review
09/12/2007 BETH GRANT COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Needs Review