Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T07CM03589
Parcel: 13624228C

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T07CM03589
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/30/2007 MARTIN BROWN FIRE REVIEW Denied Dimension indicated on sheet 418 appear to not comply with requirements for 20' wide, unobstructed access. Please clarify.
11/01/2007 STEVE SHIELDS ZONING REVIEW Denied DSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: 6710 E. Golf Links Road
T07CM03589
Site review for proposed security gates and fencing (1st Review)

TRANSMITTAL DATE: November, 2007

1. This plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, Traffic and Solid Waste Review Sections and until all zoning comments or concerns have been addressed.

3. Zoning will re-review the building plan on the next submittal once the above sections have approved the plan. Additional comments may be forthcoming.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956

C:\planning\grading\t07cm03289.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents
11/01/2007 BIANCA RAMIREZ ENGINEERING REVIEW Denied DATE: November 1, 2007
SUBJECT: 1400 LF of 6' High Fencing w/ Guards - Eng. Review Site Plan
TO: Paul Turner - Signal Gates Inc.
LOCATION: 6710 E Golf Links T14S R15E Sec30, Ward 4
REVIEWER: Bianca Ramirez, CFM
ACTIVITY: T07CM03589 (2nd Review)


SUMMARY: Engineering Division of Development Services Department has received and reviewed the proposed site plan (2nd Review) for the above referenced property. Engineering Division does not recommend approval of the site plan at this time. The following items need to be addressed:

1) Plans shall show sufficient queue is provided to satisfy TDOT Traffic requirements. Traffic analysis required as determined by engineering. For questions in regards to TDOT Traffic requirements please contact Jose Ortiz, PE, Civil Engineer at 520-791-5550 x1191. Provide letter or approval from TDOT.

2) DS Sec.3-01.6.1.E: Where residential driveways front directly on a major street, adequate area will be provided on site to accommodate a vehicular turnaround area or a circular driveway. See following comments to address.

3) DS Sec.3-01.6.2.C.1: The cul-de-sac is preferred by the City of Tucson at all times for local street turnarounds because of its overall efficiency. (See Figures 20 and 21.). Plans shall show a turn around area with maneuverability depicted on planview using the minimum design vehicle.

DS Sec.3-01.6.2.C.1.d: In industrial commercial areas, the turnaround will be paved with a minimum radius of fifty-two (52) feet, measured to the face of the vertical curb or to the back of the wedge curb, whichever is provided. Provide turn around and dimension turning radius on site plan.

4) Complied

5) Obtain Environmental Services Solid Waste review and approval of design. Provide written approval from Environmental Services Solid Waste for current property. Per Patricia Gilbert 11/01/07 - no e-mail was sent to her in regards to project. Provide letter or e-mail from Environmental Services Solid Waste.

6) Complied

7) Complied

8) The design of the entrance shall allow vehicles that do not go past the gate, to turnaround without interfering with other traffic. The minimum turnaround radius shall be 52 feet. Clearly show turning radius on plan.

9) Complied

10) All other standards apply (All weather access, sight visibility triangles, pedestrian access, current ADA compliance, etc.) Indicate sight visibility triangles and pedestrian access. Fence appears that may be located within sight visibility triangle - relocate fence if it is located within sight visibility triangle.

11) DS Sec.3-01.6.2.C: Turnarounds may be designed as cul-de-sacs or "T" or "Y" shaped configurations in accordance with Sec. 3-01.6.2.C.1 and Sec. 3-01.6.2.C.2. Regarding proposed new gated entrances for existing developments with non-public right-of-ways, those existing projects where the proposed gated entrance fronts an M&SR, the plans shall provide a turn-around area that meets full requirements of DS Sec. 3-01. Bulb shape turnarounds are preferred over "T" or "Y" shape turn-arounds.

12) Complied

13) Complied

14) Complied

15) Complied

16) Dimension and label ROW

17) Provide recordation information for Mann Ave and Golf Links Road.

18) Clearly depict median and label one way travel lanes accordingly.

GENERAL COMMENTS:
Provide a revised site plan that addresses the comments provided above. Include a comprehensive response letter addressing in detail responses to all of the above comments.
Comments were written to address specific issues with sheet 4. However, comments apply to each of the proposed gates. Per review it appears that there may need to be significant modification to current proposal. A scheduled meeting may help to alleviate numerous resubmits is recommended.
Further comments may be generated upon resubmittal of the site plan. Please enclose "redlines" with the resubmittal package for reference.
If you have any questions, or to schedule an appointment, I can be reached at 837-4935.


Bianca C. Ramirez, CFM
Engineer Associate
Engineering Division
Development Services

Final Status

Task End Date Reviewer's Name Type of Review Description
11/06/2007 THAUSER1 OUT TO CUSTOMER Completed
11/06/2007 THAUSER1 REJECT SHELF Completed