Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - SITE
Permit Number - T07CM03544
Review Name: RESUBMITTAL - SITE
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
01/17/2008 | TERRY STEVENS | ZONING | REVIEW | Approved | |
01/24/2008 | SREEVES1 | ZONING HC SITE | REVIEW | Passed | |
01/24/2008 | JOE LINVILLE | LANDSCAPE | REVIEW | Approved | |
02/04/2008 | WILLDAN | ADA | REVIEW | Denied | January 31, 2008 City of Tucson Development Services P.O. Box 27210 Tucson, AZ 85726 RE: Lincoln Park Amphitheater and Gazebo (ADA/S) – 3rd REVIEW CITY OF TUCSON LOG NO. T07CM03544 WILLDAN PROJECT NO. 13881-7077 The third review for the above project has been completed. This letter contains comments which need to be addressed by written responses to each which indicate any actions taken. In order to facilitate a shorter second review, all corrections and revisions must be made on the original plans and two complete new sets of prints, along with one complete redlined set, must be returned to our office. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets, and that all changes have been highlighted with appropriate revision numbers, revision dates, and “cloud bubbles.” Pen or pencil corrections on final prints are not acceptable. This project has been reviewed for conformance ANSI A117.1-2003. Any revisions to this plan will require an additional review and approval by Willdan. Should you have questions regarding the comments herein, please contact your plans examiners, David Williams, Site Accessibility. ACCESSIBILITY COMMENTS: General Change all slopes to be ( 1 : X ) instead of ( X : 1). See redlines. Sheet 5 An accessible route shall be provided to directly connect the performance area to the assembly seating area because a circulation path directly connects the performance area to the assembly seating area. An accessible route shall be provided from performance areas to ancillary areas or facilities used by performers. Reference the 2006 IBC Section 1108.2.7. The sides of the stage are required to have handrails along the steps, apply detail 6 on sheet 9 to both sides of the steps for the stage. Reference ANSI A117.1-2003. Sheet 6 Please show the slope and cross slope of the walking path. See redlines. Reference ANSI A117.1-2003. Move the truncated domes from the center of the accessible ramp to the landing at the bottom of the ramp. See redlines for clarification. Sincerely, WILLDAN David P. Gue, P.E. City Engineer |