Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T07CM03544
Parcel: 13629003A

Review Status: Completed

Review Details: SITE

Permit Number - T07CM03544
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/31/2007 DAVE MANN FIRE REVIEW Approved
09/10/2007 TERRY STEVENS ZONING REVIEW Denied TO: Development Services Department
Plans Coordination Office

FROM: Terry Stevens
Lead Planner

PROJECT: T07CM03544
4325 S. Pantano
Site Plan

TRANSMITTAL: 09/11/07

COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. Live performances, as indicate on the plan, are grouped with the Entertainment category in the LUC. Entertainment is not an allowed use within a SR zoned property. Provide a letter of determination from the Zoning Administrator indicating this use will be allowed as a secondary use or ancillary use to the Recreation Use of the park.

2. Provide a parking calculation for all uses on the entire property including the proposed new use, clearly indicating that there is the number of required parking spaces available for all uses.

3. Per DS 2-08.5.1.C the indicated pedestrian circulation path (sidewalk0 from the parking spaces to the proposed buildings and use area is not allowed to be constructed of asphaltic concrete. This sidewalk must meet the requirements for an accessible route. Clearly indicate slope, type of materials, location of ramps if required for the sidewalk.

Provide truncated domes, per ANSI 117.1-2003 Sec. 705.5, 406.13 on the sidewalk or ramp at the transition from the vehicular use area to the sidewalk.


If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961
09/11/2007 TERRY STEVENS ZONING HC SITE REVIEW Denied see zoning comments
09/26/2007 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Approved
09/27/2007 JOE LINVILLE LANDSCAPE REVIEW Denied 1) Submit a native plant preservation plan or application for exception. LUC 3.8.4.2

2) The site contains regulatory floodplain areas that may contain riparian habitat. This habitat may not unnecessarily altered per TCC Sec. 26-5.2. Refer to DS 2-13 for the preparation, submittal, and review procedures for development within areas that have environmentally valuable habitat in conformance with Article 1, Division 1, Floodplain and Erosion Hazard Area Regulations.

3) Submit an Environmental Resource Report (ERR) per DS 2-13.2.5.B.1 if encroachment is proposed in the regulatory area. The report will document (1) the areas that contain riparian and wildlife habitat that is to be preserved and (2) those areas without such habitat within the regulatory floodplain.

4) Necessary development shall include only the crossing of riparian habitats with roadways, bikeways, paved walkways and utilities as listed below where there is no viable alternate crossing available and the crossing is necessary for the reasonable development of the property. DS 2-13.2.4.B.2

5) All tentative plats, development plans, site plans, plot plans or other plans providing for approval of development within property that includes any Regulated Area as defined in Development Standard 2-13.2.2.A shall identify and delineate the Regulated Areas and the Protected Riparian Area. Revise the plans as necessary.

6) Revise the native plant preservation plans to show the limits of grading. DS 2-15.3.4.A
Revise the landscape plans to show the limits of grading.
DS 2-07.2.2.B.5
10/01/2007 JOE LINVILLE NPPO REVIEW Denied See landscape review comments.
10/03/2007 WILLDAN ADA REVIEW Denied September 19, 2007



City of Tucson Development Services
P.O. Box 27210
Tucson, AZ 85726

RE: Lincoln Park Bike Jump Facility ADA
CITY OF TUCSON LOG NO. T07CM03544
WILLDAN PROJECT NO. 16608-7008– 1ST REVIEW

The initial review for the above project has been completed. This letter contains comments which need to be addressed by written responses to each which indicate any actions taken. In order to facilitate a shorter second review, all corrections and revisions must be made on the original plans and two complete new sets of prints, along with one complete redlined set, must be returned to our office. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets, and that all changes have been highlighted with appropriate revision numbers, revision dates, and “cloud bubbles.” Pen or pencil corrections on final prints are not acceptable.

This project has been reviewed for conformance with the City of Tucson Land Use Code 1995 and the City of Tucson Development Standards 2000 as amended and supplemented.

Any revisions to this plan will require an additional review and approval by Willdan.

Should you have questions regarding the comments herein, please contact your plans examiners, David Williams, Zoning/Landscape and David Gue, Engineering.

Zoning Site Area Building Area S.F. Overlays Use
SR 1.32 AC 576 N/A Park


ACCESSIBILTY COMMENTS:
Sheet L1
Please indicate all slopes and cross slopes for the path connecting the parking lot to the Ramada.

Please extend the sidewalk, on the east side of the parking lot, north in order to connect to the accessible path. See redlines.


Sincerely,

WILLDAN


David P. Gue, P.E.
City Engineer
DPG/cc

Final Status

Task End Date Reviewer's Name Type of Review Description
10/17/2007 VFLORES1 OUT TO CUSTOMER Completed
10/17/2007 VFLORES1 REJECT SHELF Completed