Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T07CM03532
Parcel: 138211070

Address:
7011 S 7TH AV

Review Status: Completed

Review Details: REVISION - - 2ND

Permit Number - T07CM03532
Review Name: REVISION - - 2ND
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/20/2008 DAVE WITT BUILDING-RESIDENTIAL REVIEW Denied PLAN CHECK COMMENTS - PROJECT #T08CM03532

10/20/08 7011 S. 7th AVE.

PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN.

SCOPE OF REVIEW:

THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2006 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL.

GENERAL REQUIREMENTS:

1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ¼ INCH = 1-FOOT SHALL BE USED
FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE.

2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS.

3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES.

SITE PLAN:

1. IF THERE IS GAS TO THE HOUSE, PLEASE INDICATE IT'S ROUTE.

FOUNDATION PLANS:

1. PLEASE PROVIDE A FOOTING DETAIL FOR EACH PORCH. 4/3 IS AN OVERHANG.

STRUCTURAL PLANS:

1. PROVIDE A DIMENSIONED FRAMING PLAN FOR EACH PORCH IN ¼" OR LARGER SCALE.

2. PROVIDE A CROSS SECTION OF EACH PORCH DESCRIBING CONNECTIONS, MATERIALS, AND HARDWARE.

3. SPECIFY LUMBER GRADE AND SPECIES.

SECTIONS - DETAILS - MISC. NOTES:

The notes regarding the porches appear to reference inappropriate details. I-joists and hangers, legered to masonry or frame, posts?, hardware?, ceiling? Please include this in the cross section. Provide a dimensioned framing plan and cross section for the 5'x10' porch.
If 10/3 will be the typical parapet around the house, please tie the stud to the plate and the rafter to the plate on the masonry wall,
For a continuous load path.











IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER:
DAVE WITT @ 837-4910

Final Status

Task End Date Reviewer's Name Type of Review Description
10/22/2008 CINDY AGUILAR OUT TO CUSTOMER Completed
10/22/2008 SUE REEVES REJECT SHELF Completed