Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T07CM03521
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/27/2007 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 12/18/2007 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS Activity: T07CM03521 Date: 12/19/07 Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2006 International Residential Code, 2006 International Energy Conservation Code, and Arizona State amendments to the 2006 Uniform Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. All engineers and architects involved in the design of the structure are to seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration. I. GENERAL REQUIREMENTS: " Provide two copies of the corrected set of drawings (no clouds or revision numbers please) along with a set of the first submission (cloud corrections on this set please). All corrections and revisions shall be made on original tracings or finished reproducible set. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets. II. FLOOR PLANS: " Provide protection from impact for appliances located in the carport, M1307.3.1 " Show location and size of the window(s) in the existing bedroom adjoining the addition, R310. III. STRUCTURAL PLANS: " Truss calculations must be signed, dated and wet-sealed by an engineer who is registered in Arizona. Truss calculations shall be cross-referenced to the floor plans. Note the requirement for a deferred submittal if the truss calculations will not be submitted with the plan review. " Provide additional information about the connection of the glulam to the wall on the South East corner of the carport. IV. SECTIONS - DETAILS: " Provide keynotes for the details. V. PLUMBING PLAN: " Plumbing shall comply with 2006 UPC with local amendments. The plans should reference this code, or appeal to the Building Official for 2003-design approval. " Provide information on the plumbing material 'Agua Pec'. " Verify the height of the temperature and pressure relief line (6 feet above grade?). " Specify the size of the water meter. Note: the Tucson Water policy adopted 3/2/07 limits the maximum demand for a 5/8" water meter to 10GPM, confirm with Tucson Water that the existing meter will be able to meet the new water demand. " Specify the maximum developed length of the water supply piping. VI. MECHANICAL PLAN: " Clarify the note specifying a 3x8 dryer duct. " Clarify the size of the mechanical unit (mechanical page says 2½ ton, the electrical page says 3½ ton). VII. ELECTRICAL PLAN: " Clarify whether the electrical service is existing or upgraded. " Specify the conductor size of the dryer circuit on the panel schedule. " Specify the number of circuits that will supply power to the existing electrical system on the panel schedule. VIII. OUTDOOR LIGHTING CODE " Show compliance with City of Tucson Outdoor Lighting Code with an approved lighting calculation in accordance with OLC 3.1.2. Include all exterior fixtures on the property in the calculations. " Provide cut sheets for all FCO fixtures showing the angle of cutoff, light emissions and fixture wattage. All other fixtures are assumed to be unshielded (non-FCO style). If you have any questions please contact: Clayton Trevillyan (520) 837-4913 City of Tucson Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/26/2007 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
| 12/26/2007 | SHANAE POWELL | REJECT SHELF | Completed |