Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T07CM03501
Review Name: COMMERCIAL TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/24/2007 | MICHAEL ST. PAUL | ZONING | REVIEW | Approved | |
| 08/24/2007 | LINDA BUCZYNSKI | ELECTRICAL-COMMERCIAL | REVIEW | Approved | T07CM03501 8/24/07 1. Fixture K1, apparently incandescent, shall have a source efficiency of greater than 60 lumens per watt. Reference IECC 505.6.1. 2. Please remove the redundant GND on the line side of the service disconnect. The third 3/0 will carry fault current back to the source. 3. Water heaters are specified for 208V. Please coordinate with Plumbing and verify that 240V is acceptable. Plumbing shall indicate such on plans. |
| 09/07/2007 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Approved | |
| 09/07/2007 | RBROOKS1 | BUILDING-COMMERCIAL | REVIEW | Approved | 1. DETAIL VERTICAL BRAB BAR IN RESTROOM DETAIL 2. NOTE DRINKING FOUNTAIN @ SINK 3. NOTE THE MOP SINK IN THE RESTROOM |
| 09/07/2007 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 09/07/2007 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Approved | |
| 09/07/2007 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 09/12/2007 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 09/12/2007 | JOHN WILLIAMS | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 09/12/2007 | PAUL MACHADO | ENGINEERING | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/18/2008 | SUE REEVES | APPROVAL SHELF | Completed |
| 01/18/2008 | VFLORES1 | OUT TO CUSTOMER | Completed |