| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/21/2009 | DAVE MANN | FIRE | REVIEW | Denied | Portions of the home have greater than 150 hose lay from paved street. Provide automatic fire sprinklers. |
| 09/22/2009 | MICHAEL ST. PAUL | ZONING | REVIEW | Denied | CDRC TRANSMITTAL FROM: Michael St.Paul, Planning Technician PROJECT: T07CM03499 (T07BU01779 Grad & T07OT01938 FUP) 1461 South Camino Santiago New SFR TRANSMITTAL: September 23, 2009 COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1) This review is for a proposed single-family residence (SFR) in the R-1 Zone (LUC Section 2.3.4.2.A.1). The Development Designator is "G" (LUC Section 3.2.3.1.B) and the Perimeter Yard Indicator is AA (LUC Section 3.2.6.4). 2) There appears to be a structure to the east that crosses on to this property on the northeast corner. Please confirm this location. It does not appear to be in the correct. 3) Provide the wall heights on the plot plan. Go to LUC Section 3.2.6.3 for the correct methods of measurement for setbacks. Measure from design grade (the ground to the highest point of each exterior wall of the proposed house. 4) A lot combination shall be required prior to approval of the plot plan. 5) There may be further comments relative to the information provided with next submittal. |
| 09/23/2009 | MATT FLICK | ENGINEERING | REVIEW | Denied | DSD Engineering recommends DENIAL of the site plan and offers the following comments: Compliance with the WASH Ordinance is not properly addressed. Although the SFR, in and of itself, is not subject to WASH - the remainder of development within 50 feet of the top of bank is subject to WASH. To the reviewer's knowledge, a WASH Overlay application has yet to be filed for this project. It should also be noted that disturbance of the WASH may necessitate a submittal to SAC. Please note on the plan the location of the bank, WASH Ordinance Resource Area and WASH Ordinance Study Area. The site plan will not be approved prior to approval of the WASH Overlay application. See Floodplain Permit (T07OT01938) comments for more detail. |
| 09/28/2009 | ANDREW CONNOR | LANDSCAPE | REVIEW | Denied | 1. The Regulated Area for watercourses is defined under Development Standard 9-06.2.2. B.2 & 3, Development shall not extend beyond the banks of a watercourse and the area within 50 feet of the top of the bank. 2. Delineate on the Site, Riparian Resource Map, and Riparian Mitigation Plans the location(s) of top of bank, WASH Ordinance Resource Area and WASH Ordinance Study Area. 3. WASH Overlay application has not been filed for this project. Verification and approval of special applications is necessary to continue site review. (See comments associated with Case # T07OT01938). 4. Ensure that all Engineering and Zoning comments, concerns are addressed incuding appropriate revisions and review process has been implemented. 5. Additional comments may apply. |
| 10/09/2009 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/23/2009 | CPIERCE1 | OUT TO CUSTOMER | Completed |
| 10/23/2009 | SUE REEVES | REJECT SHELF | Completed |