Permit Review Detail
Review Status: Completed
Review Details: REVISION - - 1ST
Permit Number - T07CM03341
Review Name: REVISION - - 1ST
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
12/07/2009 | RONALD BROWN | BUILDING-COMMERCIAL | REVIEW | Denied | GENERAL COMMENT: 1. Because of the complete change of all the documents from the original approved set, deletion of two sheets and adding of 11 new sheets, this project is requierd to have a complete new code review. SHEET ASP-1 1. The Site Plan must be submitted to the CDRC for approval. A copy of the approved site plan must be submitted with the drawings. SHEET S1.3 2. Please provide Special Inspectors Certificates for all the special inspections required as outlined on this sheet. STRUCTURAL DRAWINGS 3. The structural drawings for this project can not be reviewed with out a complete set of structural calculations. Please submit same. SHEET A1: 4. There are inconsistances with the section detail references: reference 7/A5.2 should be 8/A5.2. Please check all detail references and insure proper section is referenced. SHEET SP1 5. Lettering font sizes are noncompliant. Change all lettering to 3/32" minimum height upper and lower case. END OF REVIEW |
12/16/2009 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Passed | |
12/16/2009 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Provide roof drainage calculations (i.e. the roof areas served by each roof drain or scupper). All roof areas shall be drained by roof drains, scuppers, or gutters. Reference: Section 1101.11.1, UPC 2006. 2. Provide calculations to show that the size of the overflow in the roof drain collector box has a drainage capacity equal to that of the scupper. Reference: Section 1101.11.2.2.1, UPC 2006. 3. Revise the overflow drain (detail 5/A7) strainer to comply with the requirements of Section 1105.2, UPC 2006. |
12/22/2009 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Approved |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
12/23/2009 | CPIERCE1 | OUT TO CUSTOMER | Completed |