Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T07CM03265
Parcel: 113071310

Address:
3128 N CHERRY AV

Review Status: Completed

Review Details: RESIDENTIAL BLDG/ZONING/ENGINE/WWM

Permit Number - T07CM03265
Review Name: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/14/2007 PATRICIA GILBERT ENGINEERING REVIEW Denied DATE: September 17, 2007
ACTIVITY NUMBER: T07OT020272/T07CM03265
PROJECT ADDRESS: 3128 North Cherry Avenue
PROJECT REVIEWER: Patricia Gilbert

FLOODPLAIN USE PERMIT IS DENIED

RESUBMITTAL REQUIRED: SITE PLAN, FLOODPLAIN USE PERMIT APPLICATION

This property is within the FEMA Flood Hazard Area, because of this, very specific notes must be added to the site plan prior to approval. Please provide the requested information on the site plan. The comments are minimal and the next review can be conducted over the counter by the reviewer, Patricia Gilbert. To schedule a time please call at 837-4936.

1. Any structure which is substantially improved at a cost equal to or exceeding 50% of the full cash value of the structure as shown on the latest assessment rolls from the county assessor or an appraisal from a licensed appraiser with the State of Arizona. The submitted cost estimate exceeds 50% of the value of the structure. The addition must elevated one foot above the water surface elevation per the FIRM Panel. The following notes must be added to the site plan;

a. The property is subject the Floodplain Ordinance Chapter 26.
b. Add a general note to the plan that the entire property lies within a FEMA Flood Hazard Area, Zone AE
c. The water surface elevation is 2376.75' and the datum used for this elevation is NGVD 1929.
d. The required finish floor elevation of the addition must be 2377.75' NGVD 1929.
e. Provide a general note on the site plan that this development contains a requirement that the applicant, or the applicant's authorized representative, complete an Elevation Certificate and is returned to the Development Services Department (DSD) Engineering Division prior to approval of the pre-slab inspection and the final inspection. Both of the original elevation certificates must be returned to the DSD Engineering Division.
09/28/2007 GERRY KOZIOL WWM REVIEW Approved
10/08/2007 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Denied PLAN REVIEW COMMENTS T07CM03265

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken.

SCOPE OF REVIEW:
The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2006 International Residential Code, 2006 International Energy Conservation Code, and Arizona State amendments to the 2006 Uniform Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

GENERAL REQUIREMENTS:
All corrections and revisions shall be made on original tracings or finished reproducible set. Return this set and a copy along with a set of the first submission. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets.

All engineers and architects involved in the design of the structure are to seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration.

As of 6/12/2007 the City of Tucson has adopted the 2006 IRC with the exception of the plumbing portion which has been replaced with the 2006 UPC with amendments. All plans should reference these codes. See this site for all adopted amendments: http://www.tucsonaz.gov/dsd/Codes___Ordinances/Building_Codes/building_codes.html


· Provide ¼" = 1' scaled drawings with legible notation (minimum 1/8" lettering). Replace all undersized notation or blurred lettering on sheets #2, 3 & 4.

· Interior alterations require the installation of smoke alarms if not existing, R313.2.1.


STRUCTURAL PLANS:

1. Revise the location of Type B brace wall panels on the East wall, sheet 1. Locate and identify 4' brace wall panels within 12.5' of ends for avoiding the requirement of tie-downs at panels less than 4' wide, Table R602.10.6.
2. Provide a 3" nominal ledger (rather than 6" shown on Details C & D) compliant with R606.11, or provide (post) structural support to foundation.

SECTIONS - DETAILS:

1. Provide fiber-cement board rather than moisture resistant (green) gypsum board in tub and shower areas, R702.4.2.

PLUMBING PLANS:

1. Revise the 1" water pipe diameter from the meter or the water pressure range showing compliance with UPC 610.8, Table 6-6.
2. Provide ¾" water pipe diameter from the point of connection to the new bathroom group, UPC 610.8, Table 6-6.

MECHANICAL PLANS:

1. Revise Mechanical Notes #5 & 6, sheet 5, showing supply and return ducts with minimum R-8 insulation (includes vented attics) except when completely located inside the thermal envelope, R1103.2.1. Show R-4.2 insulation when ducts are located in an unconditioned space (chase) inside the thermal envelope, IECC 503.2.7 (City of Tucson Amended).
2. Show dryer vent size and location for venting to exterior, M1501.
3. Show bathroom (toilet room) exhaust fan locations for venting to exterior with minimum 50 CFM rating R303.3 and M1507.3.

ELECTRICAL PLANS:

1. Show the Bathroom receptacle on a separate 20 AMP circuit with no other outlets, E3603.4.

INTERNATIONAL ENERGY CONSERVATION CODE:

1. Show the "U" factors of the windows on the plans as well as the solar heat gain coefficient SHGC minimum value of 0.40, N1101.2.

If you have any questions please contact:
Ken Van Karsen
(520) 837-4912
City of Tucson Residential Plan Review

Final Status

Task End Date Reviewer's Name Type of Review Description
10/10/2007 THAUSER1 OUT TO CUSTOMER Completed
10/10/2007 THAUSER1 REJECT SHELF Completed