Review Date Reviewer's Name Type of Review Description Status Comments
07/31/2007 DAVID BELL LANDFILL REVIEW Approved
08/22/2007 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Denied PLAN REVIEW COMMENTS
Activity: T07CM03122
Date: 8/22/07

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken.

SCOPE OF REVIEW:
The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2006 International Residential Code, 2006 International Energy Conservation Code, and Arizona State amendments to the 2006 Uniform Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

All engineers and architects involved in the design of the structure are to seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration.

I. GENERAL REQUIREMENTS:
· Provide two copies of the corrected set of drawings (no clouds or revision numbers please) along with a set of the first submission (cloud corrections on this set please). All corrections and revisions shall be made on original tracings or finished reproducible set. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets.

II. SITE PLAN:
· Specify overhead or underground electrical service. Electrical drops over buildings must meet service standards by TEP and E3504.2.

III. STRUCTURAL PLANS:
· Provide manufacturer's calculations and data for pre-engineered trusses dated and wet-sealed by an engineer who is registered in Arizona, or note the requirement for deferred submittal. Truss calculations shall be cross-referenced to the floor plans, R802.10.2.
· Justify 8x10 header option over garage door.

IV. ELEVATIONS:
· Specify connection between existing carport and the new garage. Include any applicable flashing needed.

V. PLUMBING PLAN:
· Provide the diameter of the water line from the meter and include the existing plumbing fixture units in the demand calculations, UPC Table 6-6.

If you have any questions please contact:
Clayton Trevillyan
(520) 837-4913
City of Tucson Residential Plan Review

Final Status

Task End Date Reviewer's Name Type of Review Description
08/29/2007 DELMA ROBEY OUT TO CUSTOMER Completed
08/29/2007 DELMA ROBEY REJECT SHELF Completed