Permit Number: T07CM03055
Parcel: 116240590

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T07CM03055
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/24/2008 BIANCA RAMIREZ ENGINEERING REVIEW Denied DATE: January 24, 2008
SUBJECT: Residence and Studio for: William and Maria Elena Maytorena
TO: Manny Delgado
LOCATION: 155 S Panorama Circle, T14S R13E Sec15, Ward 1
REVIEWERS: Bianca Ramirez, CFM
ACTIVITY: T07CM03055 (Third Review)


RESUBMITTAL REQUIRED: Site/Grading Plan

SUMMARY: Engineering Division of Development Services Department has received and reviewed the proposed site plan for the above referenced property. Engineering Division does not recommend approval of the site plan at this time. The following items need to be addressed to the next submittal:

Site Plan:

1. Please include a response letter to the comments along with the corrected copies of the Site Plan.

2. Complied.

3. Complied

4. D.S. Sec.2-02.2.1.11: Label material that is proposed for driveway. Slope of driveway exceeds maximum 15% slope per ADA.

5. Complied

6. Complied

7. Complied

8. Complied

9. Complied

10. D.S. 2-02.2.1.29: Show Grading Plan number T07BU02441 on All sheets.

11. Complied

12. See additional comments #25- #29

13. Complied

14. Complied

15. Complied

16. Complied

17. Complied

18. Complied

19. Grading information, including proposed contours and locations of all areas of cut and fill.

20. Complied

21. Complied

22. Differential grading may be applicable verify that grading is not more that 2' from existing to proposed.

23. If you would like to meet with me to review the comments please call to set up an appointment.

24. Complied

25. Provide finished floor elevation for residence and garage.

26. Grade gutter appears to concentrate flow and discharge onto adjacent property. Provide adequate area for spillway and erosion protection. In addition, provide side yard swales along northern and southern portion of parcel.

27. Provide cross sections as depicted on plans. Northern cross-section should go through the patio through property line including side yard with erosion protection. Southern cross-section should go through the sidewall through property line including side yard with erosion protection.

28. Provide bottom finished floor of balcony on plan.

29. Label type of curbing for 1' type curb.


If you have any questions, I can be reached at 520-837-4928 or Bianca.Ramirez@tucsonaz.gov

Bianca C. Ramirez
Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 837-4928 office
(520) 879-8010 fax

Final Status

Task End Date Reviewer's Name Type of Review Description
01/28/2008 CINDY AGUILAR OUT TO CUSTOMER Completed
01/28/2008 SHANAE POWELL REJECT SHELF Completed