Permit Number: T07CM03055
Parcel: 116240590

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T07CM03055
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/21/2007 GERRY KOZIOL WWM REVIEW Approved
12/04/2007 BIANCA RAMIREZ ENGINEERING REVIEW Denied DATE: December 5, 2007
SUBJECT: Residence and Studio for: William and Maria Elena Maytorena
TO: Manny Delgado
LOCATION: 155 S Panorama Circle, T14S R13E Sec15, Ward 1
REVIEWERS: Bianca Ramirez, CFM
ACTIVITY: T07CM03055 (Second Review)


RESUBMITTAL REQUIRED: Site/Grading Plan

SUMMARY: Engineering Division of Development Services Department has received and reviewed the proposed site plan for the above referenced property. Engineering Division does not recommend approval of the site plan at this time. The following items need to be addressed to the next submittal:

Site Plan:

1. Please include a response letter to the comments along with the corrected copies of the Site Plan.

2. Complied.

3. D.S. Sec.2-02.2.1.10: Label existing sight visibility triangles. Revise site visibility triangle that reads 180' to read 185'.

4. D.S. Sec.2-02.2.1.11: Label material that is proposed for driveway.

5. D.S. Sec.2-02.2.1.16: Provide additional drainage arrows throughout site and include percentage slopes.

6. Complied

7. Complied

8. Complied

9. Complied

10. D.S. 2-02.2.1.29: Show Grading Plan number T07BU02441 on all sheets.

11. Complied

12. D.S. Sec.11-01.8.2: Fill slopes shall not be constructed on natural slopes steeper than 1 unit vertical in 2 unit's horizontal (50% slope). The ground surface shall be prepared to receive fill by removing vegetation, non-complying fill, topsoil and other unsuitable materials scarifying to provide bond with the new fill and, where slopes are steeper than 1 unit vertical in 5 units horizontal (20% slope) and the height is greater than 5 feet (1524 mm), by benching into sound bedrock or other competent material as determined by the soils engineer. The bench under the toe of a fill shall be at least 10 feet (3048 mm) wide The area beyond the toe of fill is to be placed over a cut, the bench under the toe of fill shall be at least 10 feet (3048 mm) wide but the cut shall be made before placing the fill and acceptance by the soils engineer or engineering geologist or both as a suitable foundation of fill. Call out fill slopes on site.

13. Complied

14. D.S. Sec.11-01.9.2: 2' setback from property line is required. Or notarized letter from neighbor is needed permuting disturbance to occur within 2' of property line.

15. Complied

16. DS Sec.2-05.1.4.H.2: Review and approval from TDOT Permits and Codes for all proposed improvements including sidewalk within the public right of way will be required. A right-of-way use permit application will be required prior to construction. Contact Steve Tineo at 741-3115 for all right-of-way requirements and permit applications.

17. Complied

18. Complied

19. Grading information, including proposed contours and locations of all areas of cut and fill.

20. Complied

21. Complied

22. Differential grading may be applicable verify that grading is not more that 2' from existing to proposed.

23. If you would like to meet with me to review the comments please call to set up an appointment.

24. Add grading note: "Depress all landscaped areas a maximum of 6" for water harvesting"

If you have any questions, I can be reached at 520-837-4928 or Bianca.Ramirez@tucsonaz.gov

Bianca C. Ramirez
Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 837-4928 office
(520) 879-8010 fax
12/11/2007 DAVE WITT BUILDING-RESIDENTIAL REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
01/02/2008 CPIERCE1 OUT TO CUSTOMER Completed
12/24/2007 SUE REEVES REJECT SHELF Needs Review