Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T07CM02977
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/20/2007 | DAVE WITT | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T07CM02977 8/21/07 2033 E. HIDALGO VISTA PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN. SCOPE OF REVIEW: THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2006 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL. GENERAL REQUIREMENTS: 1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ¼ INCH = 1-FOOT SHALL BE USED FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE. 2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS. 3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES. FLOOR PLANS: 1. WHAT WILL THE "NEW SOUTH WEST ROOM" BE USED FOR? BEDROOM, DEN, OFFICE,……? 2. PLEASE, DESCRIBE THE BOTTOM PLATE OF THE COMMON WALL BETWEEN THE KITCHEN EXTENSION AND THE " NEW SOUTH WEST ROOM" AND THE WALL'S CONNECTION TO THE FLOOR. STRUCTURAL PLANS: 1. ROOF FRAMING GENERAL NOTE #D / 5 ; 1450 IS NO LONGER THE REPETITIVE VALUE OF #2 D.F. PLEASE UPDATE. 2. PLEASE SPECIFY THE HOLD-DOWNS USED ON THE BRACED WALL PANELS. SECTIONS - DETAILS - MISC. NOTES: 1. B / 8 ; PROVIDE A CONNECTION BETWEEN THE 3-2 X 8s AND THE TRUSS ABOVE. 2. B / 8 ; PLEASE SPECIFY THE BEAM SEATS FOR THE 3-2 X 8s. PLUMBING PLANS: 1. NOTE AND SPECIFY ALL PIPING MATERIALS. 2. WASTE ISOMETRIC / 9 ; THE 1 ½" VENT IS ENLARGED TO 2" VTR? TYPO? 3. WASTE ISOMETRIC / 9 ; THE VENT PIPE OPENING ISN'T PERMITTED TO BE BELOW THE WEIR OF THE TRAP. SEE UPC 905.5 . IECC: 1. PROVIDE THE U-VALUE FOR THE 3040 IN THE KITCHEN EXTENSION. SEE IRC TABLE R1102.1 OR THEIECC IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: DAVE WITT @ 837-4910. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/24/2007 | GERARDO BONILLA | OUT TO CUSTOMER | Completed |
| 08/24/2007 | GERARDO BONILLA | REJECT SHELF | Completed |