Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T07CM02917
Review Name: COMMERCIAL TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
07/23/2007 | HEATHER THRALL | ZONING | REVIEW | Approved | |
07/23/2007 | RSHERRY1 | WWM | REVIEW | Passed | |
07/23/2007 | LINDA BUCZYNSKI | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
07/23/2007 | ANY | ENGINEERING | REVIEW | Approved | |
07/23/2007 | CHRIS KIEL (WILDAN) | BUILDING-COMMERCIAL | REVIEW | Denied | 1) Please indicate on the plans the total costs associated for this project ans show that either 20% of the cost has been spent increasing accessibility or that the facility is fully accessible per section 3409.7 of the 2006 IBC.COMMENT REMAINS: Please provide verification that the installation of the grab bars and toilet paper and paper towel dispensers will cost the denoted $3,600 in order to verify compliance with section 3409.7 (i.e. construction estimates, etc.). 2) Please provide additional information regarding the location of exit signage and emergency power for egress illumination in accordance with sections 1011 and 1006.3 of the 2006 IBC for the entire tenant space. Please be sure to provide the emergency power for the lights on the exit discharge side of the required exits. COMMENT REMAINS: The current submittal still doesn't provide any information regarding the emergnecy power for the egress illumination, both on the interior and exterior side of the new tenant space. Please revise in accordance with section 1006.3 of the 2006 IBC. |
07/23/2007 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | 1. Comment not adequately addressed. Provide calculations to show that the revised ductwork will distribute the specified air flow quantities within the capabilities of the existing air conditioner. Reference Section 603.2, IMC 2003. 2. Clarify the airflow quantities for the existing diffusers. 3. Revise the ventilation calculations per Sections 403.3 and 403.3.2, IMC 2003, using the appropriate occupancies (e.g. retail sales, basement and street). 4. Revise the font size to a minimum of 1/8", all uppercase. |
07/24/2007 | DAVE MANN | FIRE | REVIEW | Approved | |
08/03/2007 | BETH GRANT | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Needs Review |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
08/03/2007 | DELMA ROBEY | OUT TO CUSTOMER | Completed |