Review Date Reviewer's Name Type of Review Description Status Comments
08/29/2007 ELIZABETH EBERBACH ENGINEERING REVIEW Approved DATE: August 31, 2007
TO: CH2MHill / Blue Mesa Studios
SUBJECT: Kinder Morgan pipeline maintenance Resubmittal Review
REVIEWER: Elizabeth Eberbach
ACTIVITY NUMBERS: T07CM02836, T07OT01888

SUMMARY: Engineering Division of Development Services Department reviewed the revised submittal packages for the floodplain use permit application, and the combo permit application submittal. Engineering recommends approval with conditions to the permit to be addressed during and post-construction. The ERR-drainage report was submitted 21AUG07 with the Floodplain Use Permit and is accepted by Engineering. Portions of the SWPP report (sealed copy, General Permit, and NOI) were submitted 21AUG07 to address and complete the SWPPP documents. The following conditions apply:

PERMIT CONDITIONS:
THE FOLLOWING 8 CONDITIONS APPLY TO PERMITS T07CM02836, T07OT01888:
1) CALL FOR PRE-CONSTRUCTION MEETING, AND SWPPP INSPECTIONS. FOR A DSD ENGINEERING INSPECTION, CALL IVR (740-6970), OR CONTACT DSD ENGINEERING AT 837-4888, OR SCHEDULE INSPECTIONS ONLINE AT: HTTP://WWW.CI.TUCSON.AZ.US/DSD/ONLINE_SERVICES/ONLINE_PERMITS/ONLINE_PERMITS.HTML
2) THIS PERMIT IS ONLY FOR THE EL PASO GAS LINE MAINTENANCE ONLY AS SHOWN ON THE APPROVED PLANS TO INCLUDE PIPELINE INSTALLATION, PROPER BACKFILLING, AND REVEGETATION. ADDITIONAL SEPARATE PERMITS ARE REQUIRED ANY OTHER ACTIVITY FOR THIS PROJECT.
3) THE PERMITEE SHALL NOTIFY THE DSD WHEN THE PROJECT IS READY FOR FINAL INSPECTION. FINAL APPROVAL SHALL NOT BE GIVEN UNTIL ALL WORK, INCLUDING ESTABLISHMENT OF ALL PERMANENT EROSION CONTROL MEASURES HAVE BEEN COMPLETED IN ACCORDANCE WITH THE APPROVED NPPO PLANS, SITE PLAN, AND ALL CONDITIONS OF PERMITS ARE COMPLETED.
4) A MINIMUM COMPACTION OF 85% OF MAXIMUM DENSITY SHALL BE PROVIDED AT FLOODPLAIN CROSSING AREAS AND ALL OTHER TRENCH BACKFILL AREAS, EXCEPT FOR PAVED ROADWAYS AND SHOULDER AREAS WHERE A MINIMUM OF 95% COMPACTION IS REQUIRED.
5) ALL COPIES OF CONSTRUCTION REPORTS, INCLUDING COMPACTION REPORTS WITH SPECIAL INSPECTION REPORTS AT THE FLOODPLAIN LOCATIONS, ARE REQUIRED TO BE SUBMITTED TO ENGINEERING DIVISION DEVELOPMENT SERVICES DEPARTMENT CITY OF TUCSON. THESE REPORTS SHALL BE SEALED BY A GEOTECHNICAL REGISTRANT OF THE STATE OF ARIZONA.
6) THERE SHALL BE NO DISTURBANCE OUTSIDE OF THE DISTURBANCE/GRADING LIMITS OR AS INDICATED ON EASEMENTS OR AGREEMENTS. WORK MAY ONLY OCCUR WITHIN THE TEMPORARY WORK SPACE AGREEMENTS AND EASEMENTS. FURTHER REVIEW AND ADDITIONAL PERMITS MAY BE NEEDED IF ADDITONAL WORK SPACE AREA IS NEEDED FOR STOCKPILING TRENCH MATERIAL / EQUIPTMENT, VEHICULAR ACCESS, OR OTHER CONSTRUCTION AREA.
7) THERE SHALL BE NO STOCKPILING OF: TRENCH FILL, EQUIPTMENT, OR VEHICLES, IN THE FLOODPLAIN. WORK IN THE FLOODPLAIN AREAS DL2 AND DL3 SHALL PROMPTLY REMOVE ANY MATERIALS ON A DAILY BASIS.
8) ANY WORK WITHIN THE CITY'S RIGHT-OF-WAY MAY NEED A RIGHT-OF-WAY USE PERMIT. CONTACT TDOT PERMITS AND CODES REGARDING ROW USE PERMITTING.

If you have any questions, I can be reached at (520) 837-4934.

Elizabeth Eberbach, PE, CPM, CFM
Civil Engineer
Engineering Division
Development Services
City of Tucson
09/04/2007 JOE LINVILLE LANDSCAPE REVIEW Approved
09/04/2007 JOE LINVILLE NPPO REVIEW Approved