Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T07CM02814
Review Name: COMMERCIAL TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
07/02/2007 | HEATHER THRALL | ZONING | REVIEW | Approved | |
07/02/2007 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Approved | |
07/02/2007 | LINDA BUCZYNSKI | ELECTRICAL-COMMERCIAL | REVIEW | Denied | T07CM02814 7/2/07 1. Provide load calculations for the panel. Demonstrate that no phase is overloaded. 2. Provide voltage level for dishwasher and heater, and all other electrical requirements. |
07/02/2007 | ROBERT SHERRY | WATER | REVIEW | Approved | |
07/02/2007 | LEERAY HANLY | BUILDING-COMMERCIAL | REVIEW | Approved | |
07/02/2007 | PATRICIA GILBERT | ENGINEERING | REVIEW | Approved | |
07/02/2007 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Provide a floor drain in the scullery. Reference Sections 412.2.2 and 704.3, UPC 2003. 2. Provide a direct waste connection for the wash and rinse sections of the 3-compartment sink, with an indirect connection for the sanitizing compartment only. Reference Sections 304.0 and 801.2, UPC 2003. 3. Provide upper terminal cleanouts on horizontal drainage pipes exceeding 5 feet in length (horizontal drain lines serving sinks require cleanouts regardless of length). Reference Section 707.4, UPC 2003. 4. Provide cleanouts sized per Section 707.11, UPC 2003. |
07/02/2007 | DAVE MANN | FIRE | REVIEW | Approved | |
07/03/2007 | DROBEY1 | WWM | REVIEW | Needs Review | |
07/03/2007 | BETH GRANT | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Needs Review |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
07/03/2007 | DELMA ROBEY | APPROVAL SHELF | Completed |
07/03/2007 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
07/03/2007 | DELMA ROBEY | REJECT SHELF | Completed |