Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T07CM02711
Review Name: COMMERCIAL TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/05/2007 | MICHAEL ST. PAUL | ZONING | REVIEW | Approved | |
| 07/05/2007 | ANY | ENGINEERING | REVIEW | Approved | |
| 07/05/2007 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. The maximum temperature of the tempered water for a public lavatory is 110 degrees fahrenheit per Section 804.3, IECC 2003. 2. A 3/4" supply to a urinal flush valve will result in a water velocity that exceeds 8 feet per second (1 GPF over a flush cycle of approximately 4 seconds results in an average flow of about 15 GPM). |
| 07/05/2007 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Approved | |
| 07/09/2007 | BETH GRANT | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Needs Review | |
| 07/09/2007 | DROBEY1 | BUILDING-COMMERCIAL | REVIEW | Needs Review | |
| 07/09/2007 | DROBEY1 | WWM | REVIEW | Needs Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/09/2007 | DELMA ROBEY | OUT TO CUSTOMER | Completed |