Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T07CM02684
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/24/2007 | RONALD BROWN | BUILDING-COMMERCIAL | REVIEW | Denied | 1. REVISIONS FOR FIRST DENIED SUBMITTAL ARE ACCEPTABLE NEW 2ND DENIED CORRECTIONS ARE NOTED BELOW: 2. PLEASE PROVIDE AN ACCURATE EXISTING SITE PLAN SHOWING THE FOLLOWING: a. EXTENT OF LANDSCAPE AND BUILDING DEMOLITION b. GRADING, DRAINAGE AND RETENSION BASIN 3. PLEASE DEFINE MORE CLEARLY THE EXTENT OF THE NEW CONCRETE/CMU SITE WALLS, THE EXISTING NOTES ARE CONFUSING. PROVIDE DEMISION LENGTHS. 4. DEFINE MORE CLEARLY THE LOCATION OF DETAIL 6/S2 IN RELATION TO THE RETENSION BASIN WHICH IS NOT SHOWN ON THE SITE PLAN 5. PROVIDE STRUCTURAL ANALYSIS AND REPORT SIGNED AND SEALED BY A STRUCTURAL ENGINEER THE STRUCTURAL CAPABILITIES OF THE EXISTING STEEL FRAME TO SUPPORT THE NEW DOUBLE INSULATED GLAZING PANELS. 6. PROVIDE WINDOW MANUFACTURER DETAILED CUT SHEETS AND STRUCTURAL SPECIFICATION REQUIREMENTS ON HEAD, JAMB, SILL AND INTERMEDIATE MUTTIN/MULLION GLAZING AND FRAMING DETAILS. 7. PROVIDE SOILS REPORT PROVIDING ACTUAL SUBSURFACE SOIL CONDITIONS AND CAPACITIES FOR PROPER STRUCTURAL ENGINEERING DESIGN. 8. SHEET A1/NOTE 7, WHERE IS SHEET A-13? |
| 10/27/2007 | PATRICIA GILBERT | ENGINEERING | REVIEW | Denied | DATE: October 27, 2007 ACTIVITY NUMBER: T07CM02684 PROJECT NAME: Catatlina American Baptist Church PROJECT ADDRESS: 1900 North Country Club PROJECT REVIEWER: Patricia Gilbert, Engineering Associate The following items must be revised or added to the site plan. Please include a response letter with the next submittal that states how all comments have been addressed. RESUBMITTAL REQUIRED: SITE PLAN 1. This office acknowledges the proposed wall(s) are located within the future sight visibility triangle (SVT). All new development must comply with the Development Standards. Given the existing structure (to be demolished) is located within the future SVT a Development Standard Modification Request (DSMR) may be approvable. Prior to submittal of the DSMR it is recommended to seek preliminary approval from Jose Ortiz (837-6730)with Traffic Engineering, Department of Transportation and Matt Flick (837-4931) with the Engineering Division, Development Services Department. |
| 10/30/2007 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Provide a vent to protect each trap for the indirect waste receptors (funnel drains). Reference Sections 901.0, UPC 2003, as amended by the City of Tucson. 2. The minimum size of drainage piping shall be as shown in Table 7-5, UPC 2003. Reference Section 703.2, UPC 2003. |
| 10/30/2007 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Approved | |
| 10/30/2007 | ROBERT SHERRY | WATER | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/13/2007 | GERARDO BONILLA | OUT TO CUSTOMER | Completed |
| 11/13/2007 | GERARDO BONILLA | REJECT SHELF | Completed |