Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T07CM02679
Review Name: COMMERCIAL TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
09/24/2007 | LINDA BUCZYNSKI | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
10/02/2007 | LEERAY HANLY | BUILDING-COMMERCIAL | REVIEW | Approved | |
10/08/2007 | ROBERT SHERRY | WATER | REVIEW | Denied | 1. Comment not addressed. If the building is served by a single water meter and currently has a reduced pressure backflow prevention assembly located immediately downstream of the meter, note its presence and size on the drawing. Reduced pressure backflow prevention assemblies shall be installed directly after the water meter for multi-use commercial buildings and for buildings with food service. Reference COT Ordinance 9976, http://www.tucsonaz.gov/water/docs/backflow-ord.pdf |
10/08/2007 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. No valves shall be located between the thermal expansion tank and the water heater. Reference Section 608.3, UPC 2003. 2. Relocate the new reduced pressure backflow preventer to conform to the access and clearance requirements of Section 603.2.3, UPC 2003. |
10/08/2007 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Approved | |
10/11/2007 | GERRY KOZIOL | WWM | REVIEW | Approved |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
10/15/2007 | SUE REEVES | OUT TO CUSTOMER | Completed |
10/15/2007 | SUE REEVES | REJECT SHELF | Completed |