Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T07CM02550
Parcel: 10512024D

Address:
4040 N ORACLE RD

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T07CM02550
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/27/2008 DROBEY1 MECHANICAL-COMMERCIAL REVIEW Needs Review
08/27/2008 JOHN WILLIAMS COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Needs Review
08/27/2008 DROBEY1 PLUMBING-COMMERCIAL REVIEW Needs Review
08/27/2008 LOREN MAKUS ENGINEERING REVIEW Needs Review
08/27/2008 DROBEY1 WWM REVIEW Needs Review
09/05/2008 LINDA BUCZYNSKI ELECTRICAL-COMMERCIAL REVIEW Denied TRANSMIT ORIGINAL DRAWINGS WITH NEXT SUBMITTAL.

PLEASE CALL AT 520.837.4907 OR EMAIL AT Linda.Buczynski@tucsonaz.gov
IF YOU CARE TO DISCUSS.

1. Sheet E221. RTU-15 takes 30A fuse, maximum, per Mechanical Plans. Specify such on this sheet. Typical. PREVIOUS COMMENT. When the manufacturer specifies a fuse, then a fuse shall be used to satisfy the requirements for MOPD. Mechanical schedule sheet has not changed from this designation. And this may be a mechanical typo, because the same schedule calls for circuit breakers factory installed. NOT RESOLVED. FUSES ARE STILL SPECIFIED ON SHEET M141.
2. Sheet E601. Values for electrical requirements for VAVs used on this sheet are different from those on the Mechanical Schedule. Please clarify. PREVIOUS COMMENT. Please recheck this. For example, VAV-4-2 is 4.0 KW on the Mechanical Schedule and 2.5 kW on Sheet E601, and VAV-4-3 is 277V 1-phase on the Mechanical Schedule and 480V 3-phase on Sheet E601. NOT RESOLVED. STILL NOT COORDINATED WITH SHEET M141.
3. Tucson Electric Power Company published Available Fault Current for a 3000A capacity 277/480V 3-phase service is 52,400A, per SR-510 Pg. 1 of 1, for the case of a single serving transformer. If there are only 45,744A available at the end of the utility cable run, please document any and all supporting information. REVIEW BEGUN WITH THIS INFORMATION. Available fault current at HL-5 and HL-6 are 39815 and 42680 respectively, which exceeds their rating of 35K. Please recheck these and all others which may apply, but note that the following appear to be OK with respect to fault current rating: ATS-1, ATS-2, LD-1, LP-13, LP-14, LP-15, LP-18, LP-19, and LP-20.
4. Assemble at least one good set for final signature.

Final Status

Task End Date Reviewer's Name Type of Review Description
09/11/2008 DELMA ROBEY OUT TO CUSTOMER Completed