Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - SITE ALL
Permit Number - T07CM02466
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/29/2009 | DAVE MANN | FIRE | REVIEW | Approved | |
| 04/29/2009 | RONALD BROWN | ZONING HC SITE | REVIEW | Approved | |
| 04/29/2009 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Denied | DATE: April 29, 2009 ACTIVITY NUMBER: T07CM02466R PROJECT NAME: Hazen Office Building PROJECT ADDRESS: 3314 North Country Club Road PROJECT REVIEWER: Bianca Ramirez, CFM, Engineering Associate The following items must be revised or added to the site plan prior to approval. RESUBMITTAL REQUIRED: SITE PLAN 1. Please include a comment letter outlining each change on the revised site plan. Specifically indicate why sidewalks and driveway apron have been deleted from site plan. 2. Correct numbering of pages 1 of 3, 2 of 3 and 3 of 3. 3. Please note that site plan and grading plan must match. Specifically, call out depressed curbs on site plan. 4. Additional comments may be following. If you have any questions, please contact me at bianca.ramirez@tucsonaz.gov or 520-837-4928. Bianca Ramirez Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837-4928 (520) 879-8010 fax |
| 05/04/2009 | ANDREW CONNOR | NPPO | REVIEW | Approved | |
| 05/04/2009 | ANDREW CONNOR | LANDSCAPE | REVIEW | Denied | 1. Submit previously approved landscape plan with next submittal for reference. 2. The site plan and landscape plan must show identical site layout to avoid conflict between the two plans. Ensure that all changes to the site plan are reflected on the landscape plan. 3. Ensure that all Engineering comments and concerns are addressed. 4. Additional comments may apply. |
| 05/14/2009 | STEVE SHIELDS | ZONING | REVIEW | Denied | DSD TRANSMITTAL FROM: Steve Shields Lead Planner PROJECT: Hazen Office Building T07CM02466 Site Plan (Revision - 1st Review) TRANSMITTAL DATE: May 14, 2009 COMMENTS: Please resubmit revised drawings and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. This site plan was reviewed for compliance with the City of Tucson Development Standards (D.S.) and Land Use Code (LUC) for full code compliance. 2. There is an existing telephone pedestal shown north of the entrance off of N. Cardi Blvd that appears to be within the proposed sidewalk, please clarify. 3. Please explain why sheets 2 of 3 and sheet 2.0 both have site plans. It appears that sheet 2.0 should be the revised site plan. 4. Based on the last approved site plan in The City of Tucson's records, approved by the Zoning review section on 08/15/08, see attached plan, this revision should be revision 4, please clarify. 5. Ensure that all changes to the site plan are reflected on the landscape plan. 6. Additional comments may be forth coming depending on how each comment has been addressed. 7. Once the above comments have been addressed Zoning is will to provide an over-the-counter review. Please call or email to schedule an appointment for this over-the-counter review. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956. C:\planning\site\t07cm02466R.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents |
| 05/18/2009 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Approved |