Permit Number: T07CM02414
Parcel: 10712231B

Review Status: Completed

Review Details: RESUBMITTAL - SITE

Permit Number - T07CM02414
Review Name: RESUBMITTAL - SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
12/11/2007 ANDREW CONNOR LANDSCAPE REVIEW Denied 1. A 5' wall is required to screen office zoned properties from vehicle use area per LUC Table 3.7.2-I. Identify the zoning for adjacent lot to the south.

2. Revise the landscape plan to show the locations, height and materials for proposed or required screen walls as shown on the site plan per DS 2-07.A.3.

3. An unpaved planting area, which is a minimum of thirty-four (34) square feet in area and four(4) feet in width, must be provided for each canopy tree within vehicle use area. Verify planter width for tree adjacent to pedestrian access.

4. Landscape plan shall include irrigation specification design and layout per DS 2-06.5.4.A & DS 2-06.5.4.B including source of irrigation, sleeves for driveways and sidewalks, locations of valves, low-flow bubblers or drip irrigation.

5. Additional comments may apply.