Permit Review Detail
Review Status: Completed
Review Details: REVISION - - 2ND
Permit Number - T07CM02412
Review Name: REVISION - - 2ND
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/12/2008 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Approved | PLAN REVIEW COMMENTS T07CM02412 R2 Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2006 International Residential Code, 2006 International Energy Conservation Code, and Arizona State amendments to the 2006 Uniform Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL REQUIREMENTS: All corrections and revisions shall be made on original tracings or a finished reproducible set. Return two sets along with a set of the first submission for reference. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets (clouded revision notation is not necessary for comment changes). All engineers and architects involved in the design of the structure are to seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration. PLUMBING PLANS: 1. Provide a 1" water supply pipe from the meter to a branch with no more than 14 fixture units of remaining load for a 3/4" pipe size, UPC 610.8, Table 6-6. 2. Show the location of the building (water) shut off valve and any hose bibb, UPC 605.3. 3. Provide a 1-1/4" gas supply pipe from the meter to a branch with no more than 173,000 BTU of remaining load for a 1" pipe size, and no more than 92,000 BTU remaining load for a 3/4" pipe size, UPC 1217.2, & Table 12-7. If you have any questions please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/13/2008 | VFLORES1 | OUT TO CUSTOMER | Completed |
| 03/13/2008 | SHANAE POWELL | REJECT SHELF | Completed |