Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T07CM02339
Parcel: 141012030

Address:
5336 S CIVANO BL

Review Status: Completed

Review Details: RESIDENTIAL BLDG/WWM

Permit Number - T07CM02339
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/27/2007 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Denied PLAN REVIEW COMMENTS T07CM02339 Revised 10/29/2007

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken.

SCOPE OF REVIEW:
The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2003 International Residential Code, 2003 International Energy Conservation Code, and Arizona State amendments to the 2003 Uniform Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

GENERAL REQUIREMENTS:
All corrections and revisions shall be made on original tracings or finished reproducible set. Return this set and a copy along with a set of the first submission. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets.

All engineers and architects involved in the design of the structure are to seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration.

As of 6/12/2007 the City of Tucson has adopted the 2006 IRC with the exception of the plumbing portion which has been replaced with the 2006 UPC with amendments. All plans should reference these codes. See this site for all adopted amendments: http://www.tucsonaz.gov/dsd/Codes___Ordinances/Building_Codes/building_codes.html

FLOOR PLANS:

1. Label adjacent rooms on the floor plan with enclosed windows, R106.1.1. A Bathroom w/o an opening window requires a 50 CFM exhaust fan, R303.3.
2. Show roof projections extending into the 3-foot fire separation distance with not less than one-hour fire-resistive construction on the underside on sheet A2.0, R302.1 (City of Tucson Amended).

STRUCTURAL PLANS:

1. Correct the design criteria on plans. Show the floor live load as PSF and the roof dead load as 15 PSF on sheet A2.0, R301.1. (City of Tucson Amended).
2. Show a ledger nail size consistent for 2x material (16d common) Table R602.3(1), also provide sufficient nailing of existing ledger for new floor load on sheet A1.0.

ELEVATIONS:

1. Provide the spiral stairs manufacturer and model on sheet A1.0, R301.1.

INTERNATIONAL ENERGY CONSERVATION CODE:

1. Show the "R" value of floor insulation and the "U" factors of the windows and doors on the plans as well as the solar heat gain coefficient SHGC minimum value of 0.40, N1101.2. Show placement of floor and roof insulation.
2. Both standard and high density R-30 batt insulation requires a space greater than provided with 2" x 8" framing. Identify the product and space that provides the intended value on the plans.

If you have any questions please contact:
Ken Van Karsen
(520) 837-4912
City of Tucson Residential Plan Review

Final Status

Task End Date Reviewer's Name Type of Review Description
02/06/2008 DELMA ROBEY OUT TO CUSTOMER Completed
02/06/2008 DELMA ROBEY REJECT SHELF Completed