Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - SITE
Permit Number - T07CM02319
Review Name: RESUBMITTAL - SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/04/2008 | PETER MCLAUGHLIN | LANDSCAPE | REVIEW | Denied | There is a dumpster shown on the site plan to be located near the northeast corner of the parking lot, which does not appear on the last approved plans. Indicate that required screening for the dumpster is met by providing a dimensioned detail of the enclosure. DS 2-02.2.1.32 |
| 03/04/2008 | PETER MCLAUGHLIN | NPPO | REVIEW | Passed | |
| 03/04/2008 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Approved | |
| 03/07/2008 | HEATHER THRALL | ZONING | REVIEW | Denied | TO: Development Services Department Plans Coordination Office FROM: Heather Thrall Senior Planner PROJECT: T07CM02319, 1333 E. 2nd Street Small addition to church and re-stripe parking lot Commercial site plan, 2nd review TRANSMITTAL DATE: March 7, 2008 COMMENTS: Please email me for a counter appointment to go over the following: A RESPONSE LETTER WAS NOT FOUND IN THE RESUBMITTAL PACKAGE, HOWEVER, I CONTINUED MY REVIEW WITH THE INFORMATION PROVIDED. 1. Per DS 2-02.2.1.6, regarding building: A) for the addition, please list the height of the building wall, from grade to top of parapet and to flat roof -for records/inspections. PLEASE RESPOND FURTHER: all I see is the note 26' per last review, not clarified how measured - and building plans indicate a wall height of 14' from FFE. If that's the case, the building addition is slightly too close to the lot line IF 2nd Street is the front street. Please declare the front street - you may choose, per LUC 3.2.6.5.B.) B) PLEASE RESPOND: Please specify ON THE SITE PLAN the addition is for the purpose of expanding the multi-purpose room (per my glance at the building plans) 2. Per DS 2-02.2.1.7, regarding setbacks: A) PLEASE RESPOND, SEE COMMENT 1.A: List both front and side street, per LUC 3.2.6.5.A (developed area) 3. Per DS 2-02.2.1.8, regarding parking: A) PLEASE RESPOND: please provide a detail of the handicapped signage, including a $518.0 fine B) PLEASE RESPOND: please declare width of the parking space adjacent to the trash enclosure, OR the distance from the trash enclosure to the parking space adjacent. Per DS 3-05.2.1.B.3, this is needed. 4. Per DS 2-02.2.1.12, regarding handicapped/pedestrian routes: A) PLEASE REVISE. per ANSI 502.4.1 and DS 2-08, the handicapped access aisle must join an accessible route to the building. Provide an accessible route to the building, ensure the route does not have cars backing out over it. THE RESPONSE PROVIDED A CROSSWALK THAT NEEDS RE-DESIGN TO ENSURE THE HANDICAPPED SPACE DOES NOT BACK OUT OVER THE CROSSWALK. B) Per this review: I acknowledge the position of the existing handicapped ramp, thank you. 5. Per DS 2-02.2.2.A.3, please provide a lot coverage calculation for the use - inclusive of building footprint (GFA) and vehicular use areas such as parking and driveways. The maximum allowed lot coverage is 70% for this use in this zone. CALCULATION INDICATED THAT AN AREA WITHIN THE CHURCH WAS USED FOR RECREATION AND WAS THEREFORE NOT INCLUDED IN THE LOT COVERAGE. PER LUC 3.2.9.3.B.2, THE SECTION DISCUSSES "TENANTS", WHICH INFERS RESIDENTIAL USE ALLOWANCE FOR A RECREATION EXCEPTION, NOT A CHURCH USE. PLEASE REVIEW AND REVISE THE CALCULATION. 6. Please note that depending upon the responses provided, further review comments may be forthcoming. I may be reached at Heather.Thrall@tucsonaz.gov or at 837-4951 should you have any questions. HCT C:\planning\site\DSD\T07CM02319 1333 e 2nd.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan |
| 03/07/2008 | HEATHER THRALL | ZONING HC SITE | REVIEW | Denied | please see zoning review comments. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/13/2008 | CPIERCE1 | OUT TO CUSTOMER | Completed |