Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T07CM02311
Parcel: 131090520

Address:
5719 E 24TH ST

Review Status: Completed

Review Details: RESIDENTIAL BLDG/ZONING/ENGINE/WWM

Permit Number - T07CM02311
Review Name: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/21/2007 SREEVES1 WWM REVIEW Denied NEED TO CLARIFY PLUMBING DRAWINGS-OLD BATH NEEDS TO BE REMOVED & WASTEWATER PLUMBING TO BE CAPPED- NEEDS WASTEWATER 8TH FLOOR CREDIT EVALUATION
07/02/2007 DAVE WITT BUILDING-RESIDENTIAL REVIEW Denied PLAN CHECK COMMENTS - PROJECT #T07CM02311

5719 E. 24th STREET 7/10/07

PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN.

SCOPE OF REVIEW:

THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2006 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL.

GENERAL REQUIREMENTS:

1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ¼ INCH = 1-FOOT SHALL BE USED
FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE.

2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS.

3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES.

4. ALL ENGINEERS AND ARCHITECTS INVOLVED IN THE DESIGN OF THE STRUCTURE ARE TO SEAL THE
RELATED SHEETS OF PLANS, DETAILS AND CALCULATIONS. THIS IS IN ACCORDANCE WITH THE RULES OF
THE STATE BOARD OF TECHNICAL REGISTRATION.

SITE PLAN:

1. PLEASE INDICATE THE LOCATION OF THE SEWER LINE ON THE PROPERTY.

FOUNDATION PLANS:

1. JUSTIFY THE ¼" RE-BAR @ 3' CENTERS. WHERE IS THIS USED? IT'S MARKED "TYP.".

2. CLARIFY " 8" TYPICAL FOOTING FOR SLAB". WHERE IS IT USED?

3. JUSTIFY THE 1" EMBEDMENT FOR ANCHOR BOLTS. SEE R403.1.6 .

4. JUSTIFY SIMPSON "MAS" @ SHEAR WALLS AND ALTERNATE SHEAR WALLS (BWP). SEE R602.10

5. ALL FOUNDATION HOLD-DOWNS AND ANCHOR BOLT SPACING FOR SHEAR WALLS SHALL BE SPECIFIED AND
LOCATED.

FLOOR PLANS:

1. PLEASE PROVIDE THE LOCATIONS OF THE HOLD DOWNS FOR THE ALTERNATE BRACED WALL PANELS.

2. PROVIDE ALL WINDOW SIZES AND TYPES, AND DESIGNATE THE OPERABLE PORTION OF WINDOWS, AS WELL
AS THE LOCATIONS OF TEMPERED GLASS PER R308.4.

3. PLEASE RENAME THE WATER CLOSET ROOM






STRUCTURAL PLANS:

1. SPECIFY DESIGN CRITERIA ON PLANS. VALUES FOR ROOF DEAD LOAD AND LIVE LOAD.

2. 2X8 @ 24"o.c. HEM-FIR STUD GRADE IS INADEQUATE FOR RAFTERS.

3. SPECIFY LUMBER GRADE AND SPECIES.

4. SPECIFY THE RIDGE.

5. SPECIFY THE PORCH RAFTERS.

6. SPECIFY THE PORCH BEAM.

7. HOW IS THE PORCH LEDGER CONNECTED TO THE WALL?

8. PROVIDE THE WINDOW AND DOOR HEADERS.

9. PLEASE USE "ARROWS" ON THE DIMENSION LINES.

ELEVATIONS:

1. PROVIDE COMPLETE DRAWINGS OF ALL ELEVATIONS. INCLUDE PATIO COVERS, DECKS, FIREPLACES AND
BAY WINDOWS. SHOW BUILDING HEIGHTS.

2. INDICATE ALL MATERIALS USED; STUCCO, CONCRETE BLOCK, GLASS BLOCK, ROOFING SYSTEMS, SIDING,
VENEERS, ETC.

3. NOTE AND SPECIFY A COMPLETE ROOFING SYSTEM: ROOFING TYPE, GRADE OF MATERIALS AND METHOD OF
INSTALLATION PER R905.

4. NOTE AND SPECIFY ALL ROOF SLOPES APPROPRIATE TO MATERIAL (SEE R905).

5. SHOW CALCULATION OF ATTIC VENTILATION AREA IN COMPLIANCE WITH R806.2. NOTE LOCATION OF ALL
VENTS NEEDED TO COMPLY.

6. NOTE GLASS IN HAZARDOUS AREAS SHALL BE SAFETY GLASS PER R308.4.

7. FOR THINCOAT STUCCO SYSTEMS OVER FOAM BOARD, NOTE AND SPECIFY THE ICBO EVALUATION REPORT
NUMBER, SYSTEM NAME AND MANUFACTURER, NOTE AND SPECIFY THE VAPOR BARRIER.

SECTIONS - DETAILS - MISC. NOTES:

1. PORCH FRAMING DETAIL / 8 ; PROVIDE A CONNECTION BETWEEN THE PORCH LEDGER AND THE WALL.

2. PORCH FRAMING DETAIL / 8 ; PLEASE SPECIFY THE POST CAP AND BASE.

3. PORCH FRAMING DETAIL / 8 ; PROVIDE A CROSS SECTION OF THE POST FOOTING W/REINFORCEMENT.

4. PORCH FRAMING DETAIL / 8 ; PROVIDE SLOPE OF ROOF ON THE CROSS SECTION.

5. PORCH FRAMING DETAIL / 8 ; DESCRIBE THE MATERIALS NEEDED FOR THE "NEW ROOF".

6. PORCH FRAMING DETAIL / 8 ; DESCRIBE THE MATERIALS NEEDED FOR THE NEW ROOF.

7. WALL SCHEDULE , EXTERIOR WALLS / 9 ; PLEASE SPECIFY WHERE THE ½" AND THE 5/8", TYPE X, GYP BD. WILL BE USED.

8. WALL SCHEDULE, INTERIOR WALLS / 9 ; PLEASE CLARIFY WHERE THE STUD SPACING MAY BE FOUND.

9. CROSS-SECTIONS SHALL BE CROSS-REFERENCED TO THE FLOOR PLAN AND FRAMING PLANS.

10. WALL SCHEDULE, NOTE / 9 ; PLEASE SPECIFY WHERE IN THE PLANS THE BRACED WALL PANELS (SHEAR WALLS) MAY BE FOUND.

11. WOOD FRAME SECTION / 9 ; PLEASE IDENTIFY THE FRAMING ANCHORS.

12. WOOD FRAME SECTION / 9 ; THE 2X8 RIDGE APPEARS TO BE INADEQUATE AS A BEAM TO SUPPORT THE RAFTERS. PLEASE JUSTIFY. SEE R802.3 .

13. WOOD FRAME SECTION / 9 ; 2X6 RAFTERS CONFLICT WITH THE 2X8 RAFTERS SPECIFIED ON THE ROOF PLAN / 6. 2X6 AND 2X8 @ 24"oc APPEAR INADEQUATE AS RAFTERS. PLEASE JUSTIFY.

14. WOOD FRAME SECTION / 9 ; PLEASE ILLUSTRATE THE CEILING JOISTS AND SPEC THEIR SIZE AND SPACING. BOTH JOISTS AND RAFTERS ARE MENTIONED. PLEASE CLARIFY.

15. WOOD FRAME SECTION / 9 ; R-30 FIBER GLASS BATT INSULATION IS 10" THICK AND DOESN'T FIT IN A 2X8 ROOF. PLEASE SPECIFY WHICH R-30 MATERIAL WILL BE USED AS ROOF INSULATION.

16. WOOD FRAME SECTION / 9 ; PLEASE IDENTIFY THE GYP. BD. SYSTEM TO BE USED ON THE EXTERIOR OF THE HOUSE. ANY STUCCO OR SIDING? A 3 COAT STUCCO COULD SERVE AS BRACED WALL PANEL OR A STRUCTURAL PANEL SHEATHING. OR IS THERE A U.S.G. LISTED SYSTEM? PLEASE CLARIFY. SEE R602.10.3 .

17. WOOD FRAME SECTION / 9 ; CLARIFY THE "6.1" @ THE DRIP CAP.

18. ENERGY CODE CROSS SECTION / 9 ; PLEASE SPECIFY THE U-VALUE OF THE WINDOWS.

19. MONOLITHIC FOOTING DETAIL / 9 ; PLEASE IDENTIFY THE NATURAL GRADE LEVEL.


PLUMBING PLANS:

1. NOTE AND SPECIFY ALL PIPING MATERIALS.

2. PROVIDE AN ISOMETRIC DRAWING OF WASTE LINES. SHOW SIZES OF WASTE LINES, VENTS AND REQUIRED
CLEANOUTS.

3. GAS: PROVIDE THE LENGTH OF LINE TO EACH APPLIANCE, BTU DEMAND OF EACH APPLIANCE, SIZE OF
EACH BRANCH, TOTAL DEMAND & TOTAL DEVELOPED LENGTH FROM METER TO MOST REMOTE
APPLIANCE ON THE SYSTEM PER UPC 1217.2

4. WATER LINE: PROVIDE TOTAL FIXTURE DEMAND & MAXIMUM DEVELOPED LENGTH. SEE UPC CHAPTER 6.

5. NOTE ON PLAN COMPLIANCE WITH WATER CONSERVATION; WATER CLOSETS 1.6 GALLONS PER FLUSH, SINKS
AND SHOWERHEADS 3 GALLONS PER MINUTE.

6. JUSTIFY THE EXISTING WATER DISTRIBUTION'S ABILITY TO ACCOMMODATE THE ADDED PLUMBING. UPC CHAPTER 6.

7. SIZE THE WATER DISTRIBUTION SYSTEM.

8. PROVIDE PRESSURE AND TEMPERATURE RELIEF VALVE AT WATER HEATER.

9. NOTE ON PLANS THAT SHOWER AND TUB / SHOWER COMBINATIONS THAT HAVE INDIVIDUAL CONTROL
VALVES SHALL BE OF THE PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE TYPE.

10. SIZE THE GAS DISTRIBUTION SYSTEM. JUSTIFY THE EXISTING SYSTEM'S ABILITY TO CARRY THE NEW LOADS.

MECHANICAL PLANS:

1. WHAT SIZE IS THE HEAT PUMP? IS IT EXISTING?

2. WHAT SIZE STRIPS (DUCT HEATER) ?

3. WHAT SIZE IS THE RETURN AIR DUCT AND FILTER FRAME?

4. WHERE IS THE RETURN AIR LOCATED? SEE M1602 .

5. SPEC's CALL FOR ROUND DUCTS, YET THE DUCTS HAVE 2 DIMENSIONS. ARE THE DUCTS ROUND OR SQUARE/RECTANGULAR?

6. PLEASE USE A HEAVIER LINE WEIGHT FOR THE DUCTS. MOVE THE DIMENSIONS OFF OF WALLS.

7. PLEASE CHECK THE DUCT SIZES.

ELECTRICAL PLANS:

1. PLEASE DRAW THE PLUMBING FIXTURES ON THE ELECTRICAL PLAN.

2. RECEPTACLES APPEAR TO BE OVER SPACED. SEE E3801.2.1 .

3. PLEASE NOTE ON PLANS, ELECTRICAL FIXTURES OVER TUBS OR SHOWERS ARE TO BE LISTED AS SUITABLE FOR USE IN WET AREAS. SEE E3903.8 .

4. PLEASE PROVIDE A CIRCUIT NUMBER BESIDE EACH ELECTRICAL DEVICE.

5. ELECTRICAL RISER DIAGRAM; PLEASE SPECIFY THE ELECTRICAL RISER AND GROUNDING SYSTEM.

6. PLEASE JUSTIFY THE EXTERIOR LIGHTING'S , EXISTING AND PROPOSED, COMPLIANCE WITH THE CITY OF TUCSON OUTDOOR LIGHTING CODE. PROVIDE CUT SHEETS FOR EXTERIOR LIGHTING FIXTURES AND BULBS.


IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER:
DAVE WITT @



ADDITIONAL PLAN CHECK COMMENTS
***** PLEASE PROVIDE THE SCALE ON EACH DRAWING *****

Final Status

Task End Date Reviewer's Name Type of Review Description
07/13/2007 THAUSER1 OUT TO CUSTOMER Completed
07/13/2007 SUE REEVES REJECT SHELF Completed