Permit Number: T07CM02274
Parcel: 12709012C

Review Status: Completed

Review Details: COMMERCIAL TI

Permit Number - T07CM02274
Review Name: COMMERCIAL TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/12/2007 CHRIS KIEL (WILDAN) BUILDING-COMMERCIAL REVIEW Denied 1) PLEASE PROVIDE EGRESS ILLUMINATION WITH EMERGENCY POWER IN ACCORDANCE WITH SECTION 1006.3 OF THE 2003 IBC. COMMENT REMAINS: THE USE OF INTERIOR LIGHTING FIXTURES DOES NOT MEET THE REQUIREMENTS OF SECTION 1006.3 (#5) FOR THE EXIT DISCHARGE. PLEASE REVISE ACCORDINGLY.
06/12/2007 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Approved
06/12/2007 LINDA BUCZYNSKI ELECTRICAL-COMMERCIAL REVIEW Approved
06/12/2007 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied The proposed point-of-use water cooler has an 1-1/2 Qt hot water tank. If this tank is greater than 3" in diameter, provide an approved temperature and pressure relief.
06/13/2007 BETH GRANT COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Needs Review
06/13/2007 TERRY STEVENS ZONING REVIEW Denied
06/13/2007 CAGUILA1 WWM REVIEW Needs Review