Permit Number: T07CM02237
Parcel: 108255470

Address:
2008 E RIVER RD

Review Status: Completed

Review Details: POST 3RD PARTY REVIEW

Permit Number - T07CM02237
Review Name: POST 3RD PARTY REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/25/2007 JOHN WILLIAMS COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed
07/31/2007 DAVE MANN FIRE REVIEW Approved
08/13/2007 HEATHER THRALL ZONING REVIEW Denied TO: Development Services Department
Plans Coordination Office

FROM: Heather Thrall
Senior Planner

PROJECT: T07CM02237
2008 E. River Road, Placita Escondida Condos (S04-178) - zoned R-3
Proposed entry arch feature, building plan, site location plan review

TRANSMITTAL DATE: August 13, 2007

COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. This project was reviewed for compliance with the Land Use Code (LUC) and Development Standards (DS). This project consists of a proposed entry feature to be constructed over the vehicle use area at the entry to the existing condominium development.

2. The last approved site plan document for the overall site was not found in the submittal package, as was listed on the submittal application as being accompanying in the submittal package. This site plan is required for further reviews of this project. Note, a smaller reference drawing of the area of proposed installation was found in the submittal package, and was used for reference in this review. The accompanying elevation drawings were also utilized for this project review.

3. The site is zoned R-3, a high density residential zoning classification. Per LUC 3.2.5.3.B, Accessory structures (within residential zones) shall not exceed 12' feet in height.

While the exact height of the structure (from grade to the highest point of the archway) is not given, the submittal indicates a height at the midpoint of the archway rafter - at the peak of the arch - is greater than 17'. Exceeding the height allowance described in LUC 3.2.5.3.B would require a Board of Adjustment variance to this section of the LUC.

4. To construct this feature over a PAAL requires that the lowest point of the archway be at minimum, 15' tall per DS 3-05.2.1.4.A. Please demonstrate that the arch area where traffic is proposed, would meet this height.

5. Per DS 3-05.2.2.B.3, a minimum of a 2' setback must be maintained between any vertical object over 6" and a PAAL. Demonstrate that the archway pillar will have a 2' setback from the vehicle use area -(i.e. curbing?)

6. Per LUC 2.3.6, the minimum setback required for the structure to the property line at the north is the greater of 10' or ¾ of the height of the structure. The proposal package indicates a letter of approval for a reduced setback was obtained from the neighboring property to the north, however, that letter was not found in the package. Please provide a copy.

7. Please provide the zoning of the adjacent parcel to the west - within Pima County limits - to determine the required setback. (It appears that the Pima County zoning to the west is SR, which requires a 25' setback, which if verified, means that the building setback to the west is insufficient.)

8. Please note that further review comments may be forthcoming, depending upon the responses provided. Should you have any questions on this review, please contact me at Heather.Thrall@tucsonaz.gov or at 837-4951. Note, should you desire to go to the Board of Adjustment to obtain a variance, all other review comments must be addressed prior to staff issuing a referral memorandum to the variance process.


If you have any questions about this transmittal, please call (520) 791-5608.

HCT C:\planning\site\DSD\T07CM02237 2008 e river.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents
08/14/2007 LOREN MAKUS ENGINEERING REVIEW Denied Provide a copy of an approved site plan showing the location of this structure on the site.

Final Status

Task End Date Reviewer's Name Type of Review Description
08/16/2007 CINDY AGUILAR APPROVAL SHELF Completed
08/16/2007 CINDY AGUILAR OUT TO CUSTOMER Completed