Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING/ENGINE/NPPO
Permit Number - T07CM02096
Review Name: RESIDENTIAL BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/07/2007 | MICHAEL ST. PAUL | ZONING | REVIEW | Denied | CDRC TRANSMITTAL FROM: Michael St.Paul, Planning Technician PROJECT: T07CM02096 2310 East Juanita Street Remodel, Addition & Demo of SFR TRANSMITTAL: June 1, 2007 COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. The plot plan submitted is for a remodel, addition and demolition of a single family residence (SFR) in the R-1 zone (LUC Section 2.3.4.2.A.1). The Development Designator is "G" (LUC Section 3.2.3.1.B) and the Perimeter Yard Indicator is AA (LUC Section 3.2.6.4). 2. Please provide copies of the last approved plot plan and floor plans. These may be retrieved from Records in Development Services. 3. Any temporary structure, such as the shed and the RV, must have a Temporary Use Permit (TUP). These permits are issued by William Balak (837-4952) on the second floor of 201 North Stone Avenue. Please be aware that sheds are seldom regarded as temporary. 4. It is not clear as to what is being added, what is being remodeled and what is being demolished on the site plan. Please refer to the plot plan instruction and model included in the returned documents. 5. See comments for T07CM01433. |
| 06/25/2007 | DAVE WITT | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T07CM02096 7/02/07 2310 E. JUANITA ST. PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN. SCOPE OF REVIEW: THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2006 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL. GENERAL REQUIREMENTS: 1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ΒΌ INCH = 1-FOOT SHALL BE USED FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE. 2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS. 3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES. 4. ALL ENGINEERS AND ARCHITECTS INVOLVED IN THE DESIGN OF THE STRUCTURE ARE TO SEAL THE RELATED SHEETS OF PLANS, DETAILS AND CALCULATIONS. THIS IS IN ACCORDANCE WITH THE RULES OF THE STATE BOARD OF TECHNICAL REGISTRATION. FLOOR PLANS: 1. THE 32" X 46" WINDOW IN THE MASTER BEDROOM APPEARS TO BE LESS THAN 24" FROM THE DOOR. PLEASE SPECIFY SAFETY GLASS, i.e. TEMPERED. SEE R308.3 AND R308.4 ITEM 6. STRUCTURAL PLANS: 1. PROVIDE A TABLE LISTING THE REQUIRED DEPTH OF THE POWERS LINTELS AND THE STEEL ARRANGEMENT. 2. PROVIDE MANUFACTURER'S DATA FOR PRE-FAB TRUSSES. TRUSS DATA MUST BE SIGNED, DATED AND WET-SEALED BY AN ENGINEER WHO IS REGISTERED IN ARIZONA. TRUSS DATA SHALL BE CROSS-REFERENCED TO THE FLOOR PLANS. 3. A4.0 ; PLEASE REVISE THE NOTE THAT SPECIFIES "P.C.B.C." TO REVIEW THE PLANS TO CITY OF TUCSON. SECTIONS - DETAILS - MISC. NOTES: 1. 1 / A5.0 ; PROVIDE AN APPROVED SPECIAL INSPECTION FORM FOR THE USE OF EPOXY AS SHOWN IN 1/A5.0. 2. 1 / A5.0 ; PLEASE SPECIFY THE BOTTOM PLATE AND IT'S CONNECTION TO THE SLAB. 3. 3 / A5.1 ; SHOULD THE SCUPPER NOTE REFER TO NOTE 2 / A5.1 ? 4. 10 / A5.1 ; WILL THE TRUSSES BE 2X4 OR 4X2? PLEASE SPECIFY THE JOIST HANGER. PLUMBING PLANS: 1. PLEASE SUBMIT AN APPROVED APPEAL TO THE BUILDING OFFICIAL FOR THE USE OF THE INTERNATIONAL PLUMBING CODE (IRC) INSTEAD OF THE UNIFORM PLUMBING CODE. IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: DAVE WITT @ 837-4910 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/03/2007 | DELMA ROBEY | OUT TO CUSTOMER | Completed |