| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/06/2007 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS Activity: T07CM02089 Date: 8/07/07 Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2006 International Residential Code, 2006 International Energy Conservation Code, and Arizona State amendments to the 2006 Uniform Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. I. GENERAL REQUIREMENTS: · Provide two copies of the corrected set of drawings (no clouds or revision numbers please) along with a set of the first submission (cloud corrections on this set please). All corrections and revisions shall be made on original tracings or finished reproducible set. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets. II. SECTIONS - DETAILS: · Both standard and high density R-30 batt insulation requires a space greater than provided with 2" x 8" framing. For the optional 2x8 roof framing assembly, identify the insulation product that provides the intended value, IECC Table 402.1.1. · Untreated exterior wood posts shall have a 6" clearance above the ground, R319.1 (5). · Show weep screeds with a minimum clearance 4" above grade or 2" above paved areas, R703.6.2.1. III. MECHANICAL PLAN: · Show supply and return ducts with minimum R-8 insulation, R1103.2.1. IV. ELECTRICAL PLAN: · Provide the location of an exterior outlet at grade level located at the back of the dwelling, E3801.7. This outlet shall be GFCI protected E3802.3. If you have any questions please contact: Clayton Trevillyan (520) 837-4913 City of Tucson Residential Plan Review |
| 08/21/2007 | PATRICIA GILBERT | ENGINEERING | REVIEW | Approved | NON-SUBSTANTIAL IMPROVEMENT Date: August 21, 2007 Address: 2832 West San Juan Terrace Permit Numbers: T07OT01594/T07CM02089 Floodplain type: COT Description of Work: Addition Type permit: Residential Year of construction of existing structure: 1978 Value of work: $ 42,341.15 Prior permit activity value $ 0 Value of structure: $ 135,675 Increase in Flood Damage Potential: % 31 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/28/2007 | THAUSER1 | OUT TO CUSTOMER | Completed |
| 08/28/2007 | THAUSER1 | REJECT SHELF | Completed |