Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T07CM01901
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
06/13/2007 | GERRY KOZIOL | WWM | REVIEW | Approved | |
06/22/2007 | BUREAU VERITAS | 2ND PARTY REVIEW | REVIEW | Denied | June 21, 2007 CITY OF TUCSON - FIRST CHECK Tucson Appl. No. T07CM01901 Bureau Veritas Job No. 01007-161001.060 Mr. Leon Sanford 131 N. Players Club Dr Tucson, Arizona 85745 Re: Plan Review: Addition Address: 131 N. Players Club Dr Dear Mr. Sanford, Bureau Veritas North America has completed a first review of the following documents on behalf of the City of Tucson: Plans: Two (2) sets of building plans (7 sheets, C1 through E1) no dates, no stamps. Structural Calculations: None submitted with this review. Truss Calculations: None submitted with this review. These documents were reviewed only for their conformance to the provisions of the 2006 International Building Codes (i.e., State of Arizona and Tucson amended 2006 IRC, 2006 IMC, and 2006 IPC). Please submit an itemized response letter and required number of complete and revised documents with all revisions clouded. Sincerely, Bureau Veritas North America Shelley Knuffke ICC Plans Examiner SK:sk Re: Stories: One Occupancy: R-3/IIIB Building Area (sq. ft.): 357 (livable) 357 Total sq. ft. A. The following plan review comments are based on the City of Tucson Building Regulations and referred to the 2006 International Building Code. B. Please respond in writing to each comment by marking the attached comment list or creating a response letter. Indicate which detail, specification, or calculation shows the requested information. Your complete and clear responses will expedite the re-check and hopefully, approval of this project. Thank you for your assistance. C. These plan review comments are based on building code items only. If site-related comments are applicable to this project, they will be generated by others (e.g., County Engineering, Public Works, Health, etc.). GENERAL REQUIREMENTS: The plan refers to 2006 code and 2003 code. Indicate that plan is drawn to current code. FLOOR PLAN COMMENTS: 1. Locate and identify heights of all ceilings. Include hallways, utility rooms, garages and walk-in closets. IRC Section R305 Landings at doors. There shall be a floor or landing on each side of each exterior door. The floor or landing at the exterior door shall not be more than 1.5 inches lower than the top of the threshold. The width of the landing shall not be less than the door served with a minimum dimension of 36 inches measured in the direction of travel. IRC Section 311.4.3. Provide energy calculations to illustrate energy efficiency. Compliance to chapter 11 shall be demonstrated by either meeting the requirements of the International Energy Conservation Code or meeting the requirements of this chapter. IRC Section N1101.2. ELEVATIONS: 1. Provide height dimensions for roofline, headers, top plate and finished floor. IRC Section R106. FOUNDATION PLAN COMMENTS: Note and specify surface drainage. IRC Section R401.3. Footing depth must be a minimum of 12 inches. IRC Section R506. All slabs and pads, including landings at all doors, shall be shown and their thickness specified. Indicate the slopes for all slabs. IRC Section 106.1, R311.4.3, and R506 FRAMING PLAN COMMENTS: Note on the plan all lumber shall bear an approved grading stamp. TRUSS SYSTEMS: Trusses can be submitted as a “Deferred Submittal”. However, they must be submitted and approved prior to their fabrication. MECHANICAL COMMENTS: Show existing water heater and T and P line. Show combustion air vents if gas is being used. PLUMBING COMMENTS: Provide a gas isometric with length of line (horizontal and vertical) to each appliance, BTU demand of each appliance, size of each branch, total demand and size of the meter. IRC Section 106.1 and Section G2402. If no gas is being used, delete all references to gas line. 2. Specify size of water meter. IRC Table 2903.1 End of Review Comments: Should you have any questions regarding the above comments, please contact Bureau Veritas North America. Shelley Knuffke at (520) 576-8400. 8:00 AM to 5:00 PM. |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
06/25/2007 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
06/25/2007 | CINDY AGUILAR | REJECT SHELF | Completed |