Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T07CM01773
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/16/2007 | GERRY KOZIOL | WWM | REVIEW | Denied | recounted all WW plumbing fixtures:needs 8th floor credit evaluation |
| 06/04/2007 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS Activity # T07CM01773 Date: 6/5/07 Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2003 International Residential Code, 2003 International Energy Conservation Code, and Arizona State amendments to the 2003 Uniform Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. I. GENERAL REQUIREMENTS: 1. All corrections and revisions shall be made on original tracings or finished reproducible set. Return this set and a copy along with a set of the first submission. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets. II. FLOOR PLAN: 1. Alternate braced wall panels on Master Bedroom are labeled SW2 (SW1?) 2. Specify lumber grade and species, R802.1. 3. Clarify references on pages S-2, S-4 to carport structure. III. ELEVATIONS: 1. Note and specify appropriate (two-layer) underlayment material for the low-slope (2:12 to 4:12) asphalt shingle roof, R905.2.7. IV. PLUMBING PLAN: 1. As of 9-02-04 the City of Tucson has adopted the 2003 UPC with amendments. Plumbing plan should reference this code. 2. Correct discrepancy on plan view for 1ΒΌ" PVC to the water meter. V. ELECTRICAL PLAN: 1. Show the laundry room exhaust fan on the electrical plan. If you have any questions please contact: Clayton Trevillyan (520) 837-4913 City of Tucson Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 06/06/2007 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 06/06/2007 | SUE REEVES | REJECT SHELF | Completed |