Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T07CM01737
Parcel: 121123710

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T07CM01737
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/04/2007 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Denied PLAN REVIEW COMMENTS for Activity # T07CM01737

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2003 International Residential Code, 2003 International Energy Conservation Code, and Arizona State amendments to the 2003 Uniform Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

GENERAL REQUIREMENTS:

All corrections and revisions shall be made on original tracings or finished reproducible set. Return this set and a copy along with a set of the first submission. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets.

All engineers and architects involved in the design of the structure are to seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration.

As of 9-02-04 the City of Tucson has adopted the 2003 IRC with the exception of the plumbing portion which has been replaced with the 2003 UPC with amendments. All plans should reference these codes. See this site for all adopted amendments: http://www.tucsonaz.gov/dsd/Codes___Ordinances/Building_Codes/building_codes.html

Construction drawing guidelines are available from the residential desk of the Development Services Division.

SITE PLAN:

1. Show the water pipe size from the meter to the building. Show the point of connection for the proposed hot and cold branches, 2003 UPC 610.1.
2. Provide a note for: Underground facility tracer wires per DSD Memo, 10/24/2005.

FOUNDATION PLANS:

1. Show a landing or floor surface at the exterior door. Landings must be at least as wide as the doors they serve and 36" in the direction of travel, R311.4.3.
2. Show or note a 6" minimum separation of untreated exterior (carport) posts above finished grade along with a 1" space above the floor, R319.1.4.
3. Show compliance with termite treatment specified by R320, as amended.
4. Show the minimum 12" footing depth below undisturbed soil (carport wall indicated on sheet 3), R403.1.4.
5. Locate and specify all anchor-bolt (J-hook) spacing on the foundation plan. Minimum ½" diameter with 7" embedment into concrete or masonry. Maximum spacing 6' o/c and within 12" of each sill plate end, R403.1.6.
6. Show the 6" minimum foundation height above finished grade (foundation detail on sheet 6), R404.1.6.

FLOOR PLANS:

1. Show that each water closet is located in a clear space not less than 30" wide (centered 15" from finished wall or fixture), IRC figure R307.2.
2. Note that tub/shower enclosures shall have nonabsorbent surfaces to 6' above the floor, R307.2. All glass enclosures shall be tempered, R308.4.5.
3. A carport shall be open on at least two sides or show as a garage, R309.4.

STRUCTURAL PLANS:

1. Locate and identify wall panel materials (show min 3/8" OSB) and locations along with the appropriate nailing schedule (8d @ 6" o/c edge & @12" o/c field), R602.10.6.
2. Note or detail trimmers and headers at framed door and window openings.
3. Provide (porch) rafter sizes in compliance with Table R802.5.1.
4. Provide manufacturer's calculations and data for pre-fabricated trusses, R802.10.2, or note the requirement for deferred submittal approval prior to installation.
5. Specify the outrigger & gable end bracing and connections to the structure, R802.10.3.
6. Show rafter to wall connection using (H2.5) ties having a resistance to uplift of not less than 175 pounds, R802.10.5.
7. Show lateral support of trusses. Show a detail of truss to wall connection using ties having a resistance to uplift of not less than 175 pounds, R802.10.5.

ELEVATIONS:

1. Show the required rafter bearing contact (carport) to supporting members (show beams), R502.6 & R802.6.
2. Note and specify a complete roofing system (addition & carport): Roofing type, grade of materials and method of installation, R905.
3. Roof shingles may be used on roof slopes of 2:12 or greater R905.2.2. Select a roof system that complies with R905.
4. Note and specify appropriate (two-layer) underlayment material for the low-slope (2:12 to 4:12) asphalt shingle roof, R905.2.7.
5. Note and specify all roof slopes appropriate with selected material, R901.1. (Minimum allowable slope for Built-up roof is ¼" per foot, R905.9.1. Minimum allowable slope for Roll roofing is 1" per foot, R905.5.2.)

SECTIONS - DETAILS - MISC. NOTES:

1. Clarify the carport structure; the plan sheet 3 shows a wall and the elevation sheet 6 shows posts. Show all carport structure connections to foundation, beams and wall top plate or ledger. Show foundation, post, beam, rafter and roof sheathing sizes.
2. Show wood framing members resting on concrete as pressure treated, R319.1(2).
3. Untreated exterior wood siding, sheathing and wall framing shall have a 6" clearance above the ground, R319.1 (5).
4. Note and specify the size, spacing and length of anchor bolts for sill plates, top plates and ledgers, R403.1.6.
5. Show a Roof Layout Plan. Provide a header schedule consistent with Table 502.5(1).
6. Note and specify all ledgers and connections to frame or masonry.
7. Show the ceiling gypsum board as either 5/8" or ½" sag resistant when applied to 24" o/c framing, IRC table R702.3.5 footnote d.
8. Show weep screeds with a minimum clearance 4" above grade or 2" above paved areas, R703.6.2.1.
9. Calculate the attic ventilation area using 1 to 150 of attic area in compliance with R806.2. Note that 50% to 80% of the required ventilating area is be provided by upper space vents when applying the reduced area calculation, or show a one perm rated vapor barrier installation.
10. Show a minimum 1" ventilation clearance between ceiling insulation and roof sheathing if insulation is attached to truss bottom cords and eave venting is used, R806.3. This may be accomplished w/ baffles.

PLUMBING PLANS:

1. Note on plans that Plumbing shall comply with the 2003 Uniform Plumbing Code with state/local amendments. The plans should reference this code, or appeal to the Building Official for IRC design approval.
2. Note and specify all piping materials, UPC 301.1.1.
3. Provide pressure and temperature relief valve at water heater. T&P line must terminate at the exterior between 6 and 24 inches above grade and must terminate facing down, UPC 608.5.
4. Show an upper terminal cleanout at each horizontal drainage pipe greater than 5'(all drains with a sink) UPC 707.4.
5. Show the cleanout size (1-½" for drains up to 2" and 2-½" for drains up to 3") as required by Table 7-6. The water closet VTR may be used as the cleanout if increased to 2-½" (3" ABS).
6. Show plumbing vents (VTR) within acceptable distances from traps (maximum 6' for water closets), UPC Table 10-1.
7. Show the length of gas line (total developed length) from meter to the most remote appliance on the system (84'), UPC 1217.2.

ELECTRICAL PLANS:

1. Note that an arc-fault circuit interrupter shall protect bedroom outlets including receptacles, lights and smoke detectors, E3802.11.
2. Note that light fixtures in clothes closets shall be installed in accordance with E3903.11.
3. Show locations of smoke detectors, R313. Note that all smoke detectors must be interconnected with a power source from the building wiring, and shall be equipped with battery backup. This includes existing bedroom smoke detectors with attic space, R313.1.1.

INTERNATIONAL ENERGY CONSERVATION CODE:

1. The simplified prescribed energy values for glazing U=0.65, ceiling R=30 and walls R=13 complies with energy requirements 2003 IECC w/ local amendments if glazing does not exceed 15% of exterior wall area. Show these values as well as the solar heat gain coefficient SHGC minimum value of 0.40.


If you have any questions, please contact your assigned plans examiner Ken Van Karsen at 791-5550, extension 1112.
05/10/2007 GERRY KOZIOL WWM REVIEW Approved