Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - SITE ALL
Permit Number - T07CM01666
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/06/2008 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
| 02/06/2008 | STEVE SHIELDS | ZONING HC SITE | REVIEW | Approved | |
| 02/07/2008 | ANDREW CONNOR | LANDSCAPE | REVIEW | Approved | |
| 03/03/2008 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Denied | DATE: March 3, 2008 ACTIVITY NUMBER: T07CM01666 PROJECT NAME: Tucson Mountain Coffee PROJECT ADDRESS: 501 West Grant Road PROJECT REVIEWER: Bianca Ramirez, CFM, Engineering Associate The following items must be revised or added to the site plan. Please include a response letter with the next submittal that states how all comments have been addressed. RESUBMITTAL REQUIRED: SITE PLAN 1. Complied 2. Be advised there are several discrepancies with the sight visibility triangles (SVTs) provided on the plan. See Development Standard Section 3-01.5.3 for Line of Sight Matrix. 3. Verify that SVT stems scale to 20'. DS 3-01.5.0. 4. Label near side existing and future sight visibility triangles (SVTs) at the northeast corner of the parcel. Correct SVT Dimension. DS 2-02.2.1.A.10. 5. The shown future SVTs for the entrance and exit drives on Grant Road are not correctly drawn on the plan. Revise the SVTs appropriately. DS 2-02.2.1.A.10. 6. Complied 7. Be advised a grading review and permit is required for this project. Submit grading plan. DS 2-02.2.1.A.17. 8. Complied 9. Complied 10. Complied 11. Complied 12. Complied If you have any questions, I can be reached at 837-4928 or Bianca.Ramirez@tucsonaz.gov Bianca C. Ramirez Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837-4928 office (520) 879-8010 fax |
| 03/05/2008 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | Comment not addressed (third request). Provide the rim elevation of the next upstream sanitary manhole. Determine the need for a backwater valve per Section 710.1, UPC 2003. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/12/2008 | CPIERCE1 | OUT TO CUSTOMER | Completed |
| 03/12/2008 | SHANAE POWELL | REJECT SHELF | Completed |