Permit Number: T07CM01666
Parcel: 115150510

Address:
501 W GRANT RD

Review Status: Completed

Review Details: SITE

Permit Number - T07CM01666
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/24/2007 DAVE MANN FIRE REVIEW Approved
05/14/2007 STEVE SHIELDS ZONING HC SITE REVIEW Denied See Zoning Comments.
05/14/2007 STEVE SHIELDS ZONING REVIEW Denied DSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: Mountain Coffee Roasters
T07CM01666
Site Plan (1st Review)

TRANSMITTAL DATE: May 14, 2007

COMMENTS: Please resubmit revised drawings and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and
Development Standards were addressed.

1. This site plan was reviewed for compliance with the City of Tucson Development Standards (D.S.) and Land Use Code (LUC) for full code compliance.

2. It appears that this project is comprised of two (2) different parcels. There are two (2) options in regards to utilizing the two (2) parcels as one site. Prior to approval of the site plan provide; 1) A Pima County Tax Parcel Combo and a recorded covenant regarding development and use of real property, or 2) Provide a site plan for each parcel that shows how the parcels can stand alone and meet the requirements of the LUC if sold separately along with a recorded covenant regarding development and use of real property.

3. D.S. 2-02.2.1.A.7. Based on a perimeter yard indicator of "DD" and LUC Sec. 3.2.6.4 Perimeter Yard Width Matrix, the required setback to the south property line, C2 zone, and the west property line, I1 zone, the setback is 0. Remove the reference setback line and dimension along the south and west property line.

4. D.S. 2-02.2.1.A.8. Provide a dimension from the northeast end of the proposed parking space, located at the north end of the proposed porch, across the parking area access lane (PAAL) as shown on the redline.

5. D.S. 2-02.2.1.A.8. Provide typical parking space detail for both handicapped and standard vehicle parking spaces. It appears that the Handicapped parking space does not meet the minimum requirements for a van accessible vehicle parking space.

6. D.S. 2-02.2.1.A.8. The handicapped sign detail does not meet the minimum requirements. The required mounting height of the sign is 7'-0" from grade to the bottom of sign, see redline.

7. D.S. 2-02.2.1.A.9. & D.S. 2-09.0 Provide off-street bicycle parking; including materials for lighting, paving, and security; fully dimensioned layout; location; specific type of rack and the number of bicycles it supports; and the location and type of directional signage if required.

8. D.S. 2-02.2.1.A.10. Provide a Far Side sight visibility triangle (SVT) for the entrance off of 13th Ave., see engineering comments.

9. D.S. 2-02.A.2.1.12. Per D.S. 2-08.4.1.A. Provide a sidewalk from Grant to the building.

10. D.S. 2-02.A.2.1.12. There does not appear to be any access from the handicapped access aisle to the sidewalk. Detectable warnings (truncated domes) will be required at all curb access ramps. ICC/ANSI A117.1-2003 Sec. 406.13. Show on the plan.

11. D.S. 2-02.A.2.1.12. It appears that the proposed bicycle parking location is utilizing a pedestrian way for access. Per D.S. 2-09.3.2 bicycle access may cross a pedestrian way at a right angle only, clarify.

12. D.S. 2-02.A.2.1.12. Clearly delineate the width of the sidewalk as it runs under the proposed porch. Minimum width of four (4) feet must be maintained.

13. D.S. 2-02.2.1.A.13. If applicable provide the location, type, size and height of existing and proposed freestanding signage and billboards.

14. D.S. 2-02.2.1.A.14. Label Grant Road as an MS&R Route.

15. D.S. 2-02.A.2.1.19. It appears that these parcels may be effected by the required MS&R taper for the intersection of Oracle and Grant, see engineering comments.

16. D.S. 2-02.2.1.A.20. If applicable show all easements of record graphically on the plan together with recording docket and page reference.

17. D.S. 2-02.2.1.A.25 If applicable provide existing and proposed freestanding lighting layout and type. Provide a detail; list the height of pole and type of lighting.

18. D.S. 2-02.2.1.A.28 The zoning shown for the parcel to the south is incorrect. Revise to read C2.

19. D.S. 2-02.A.2.1.31 Provide the "EXISTING AND PROPOSED USE" on the plan.

20. D.S. 2-02.A.2.1.32 Show refuse container location on the plan.

21. D.S. 2-02.2.2.A.3 Provide a Floor Area Ration (FAR) calculation on the plan.

22. D.S. 2-02.2.2.A.4 The parking calculation is incorrect. Commercial Services Use Group, Administrative and Professional Office requires one (1) space per two hundred (200) sq. ft. gross floor area GFR, revise the calculation. Also the square footage listed as 1,767 sq. ft. would require 9 vehicle parking spaces. This said if the square footage of the front porch is included in this calculation, and the front porch is only used for entrance to the building and pedestrian/accessible route then this area is not included in the parking calculation

23. D.S. 2-02.2.2.A.4. Provide a bicycle parking calculation to include required and provided.

24. D.S. 2-02.2.2.A.5. Provide required and provided loading zone calculation.

25. Clearly indicate on the plan the extent of perimeter wall/fence on the plan. Addition comments maybe forth coming.

26. Ensure that all changes to the site plan are reflected on the landscape plan.

27. Additional comments may be forth coming depending on how each comment has been addressed.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956.

C:\planning\site\t07cm01666.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents
05/14/2007 SSHIELD1 ADA REVIEW Passed
05/17/2007 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied 1. The applicable code for all commercial plumbing projects is the 2003 Uniform Plumbing Code with Local Amendments.
2. Revise the site drawing to show the location and size of the water meter along with the route of the water service pipe. Reference Section 103.2.3, UPC 2003.
3. Revise the site drawing to show the size and route of the natural gas service pipe from the gas meter to the building. Reference Section 103.2.3, UPC 2003.
4. Provide the rim elevation of the next upstream sanitary manhole. Determine the need for a backwater valve per Section 710.1, UPC 2003.
05/18/2007 ANDREW CONNOR LANDSCAPE REVIEW Denied 1. Submit a landscape plan to verify the entire site meets minimum requirements,

2. A street landscape border, per Sec. 3.7.2.4 of the LUC, is a landscape area with a minimum width of ten (10) feet, running the full length of the street property line(s) bounding the site except for points of ingress-egress. On streets designated as Major Streets and Routes (MS&R), the street landscape border is measured from the MS&R right-of-way line as determined by LUC 2.8.3.4.

3. Fifty (50) percent or more of the street landscape border area must have shrubs and vegetative ground cover per LUC 3.7.2.4

4. Indicate square footage of all landscaped areas and calculation of the percentage of vegetative coverage per DS 2-07.2.2.2.g.

5. One (1) canopy tree must be provided for every thirty-three (33) linear feet of landscape border per LUC 3.7.2.4.

6. A 30" continuous screen along street frontages for vehicle use area must be provided per LUC Table 3.7.2-I

7. Within a vehicular use area, one (1) canopy tree is required for each 10 motor vehicle parking spaces and every parking space shall be located within forty (40) feet of the trunk of a canopy tree (as measured from the center of the tree trunk) per LUC 3.7.2.3.A.1.

8. Planting Plan. The planting plan and layout calculations will include the following information:

§ The location of individual plants one (1) gallon or larger in size and areas to be seeded, turfed, or planted from flats.

§ Sizes of plants indicated in boxes, gallon cans

§ Ultimate size of plants indicated by the spread of canopy, circumference of shrubs, or spread of ground cover.

§ Both the proper and common name of each type of plant material.

§ Location, size, and name of existing vegetation to remain in place.

§ Material and areas of inert ground cover.

9. Submit an NPPO plan or Application for Exception; include acceptable documentation, which clearly indicates that the project will not impact Protected Native Plants.

10. Landscape plan shall include irrigation specification design and layout per DS 2-06.5.4.A & DS 2-06.5.4.B including source of irrigation, sleeves for driveways and sidewalks, locations of valves, low-flow bubblers or drip irrigation.

11. Additional comments may apply.
05/18/2007 ANDREW CONNOR NPPO REVIEW Denied Submit an NPPO plan or Application for Exception; include acceptable documentation, which clearly indicates that the project will not impact Protected Native Plants.
05/18/2007 PATRICIA GILBERT ENGINEERING REVIEW Denied DATE: May 23, 2007
ACTIVITY NUMBER: T07CM01666
PROJECT NAME: Tucson Mountain Coffee
PROJECT ADDRESS: 501 West Grant Road
PROJECT REVIEWER: Patricia Gilbert, Engineering Associate

The following items must be revised or added to the site plan. Please include a response letter with the next submittal that states how all comments have been addressed.

RESUBMITTAL REQUIRED: SITE PLAN

1. Site plan will not be approved until Lot Combination recordation is complete with Pima County. D.S. 2-02.2.1.A.2.

2. Provide a near side existing and future sight visibility triangles (SVTs) at the northeast corner of the parcel. DS 2-02.2.1.A.10.

3. Provide future SVTs for all entrance and exit drives for this property. DS 2-02.2.1.A.10.

4. Provide a far side SVT for the entrance off of 13th Avenue. The length is 110'. Label appropriately. DS 2-02.2.1.A.10.

5. All new development is to provide a sidewalk from the structure to the sidewalk located within the ROW. Provide a four foot sidewalk from the structure to the sidewalk located within the ROW for Grant Road. DS 2-02.2.1.A.11.

6. A sidewalk will be provided adjacent to any parking space accessed by a PAAL where the space is located on the same side of the PAAL as any building and no other parking spaces or PAALs intervene. Provide a 4' sidewalk between the north side of the structure and the parking space. DS 2-08.4.1.C.

7. Provide estimated cut and fill quantities for the project. If the quantities equal zero indicate on the plan. DS 2-02.2.1.A.17.

8. Indicate on the plan view if the 60' ½ ROW for Grant is existing, future or both. Label appropriately. DS 2-02.2.1.A.19.

9. In addition to the above comment, this project is subject to intersection widening per the MS & R Map. Refer to the diagram located on the lower left hand corner of the MS & R Map found on the following web page, http://www.ci.tucson.az.us/planning/maps/city/msr.pdf. Revise and label the site plan accordingly and show dimensions.

10. Dimension from street centerline to the sidewalk shown within the ROW for Grant Rd. and dimension the sidewalk on the plan view. Label the sidewalk existing or proposed. DS 2-02.2.1.A.19.

11. All easements of record must be graphically shown on the plan with recordation data; dicket and page. Provide required information if applicable. DS 2-02.2.1.A.20.

12. Keynote "G" indicates a trash enclosure per SD 3. It is not clear what, "SD 3" is indicating. Is this referencing a development standard? Please clarify.

13. Provide a detail of the solid waste enclosure. DS 6-01.

Final Status

Task End Date Reviewer's Name Type of Review Description
06/07/2007 DELMA ROBEY APPROVAL SHELF Completed
06/07/2007 DELMA ROBEY OUT TO CUSTOMER Completed
06/07/2007 GERARDO BONILLA REJECT SHELF Completed