Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T07CM01660
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/20/2007 | BUREAU VERITAS | 2ND PARTY REVIEW | REVIEW | Denied | July 19, 2007 CITY OF TUCSON - SECOND CHECK Tucson Appl. No. T07-CM01660 Bureau Veritas Job No. 01007-161001.054 Re: Plan Review: Jensen Addition Address: 3032 E. 17th St. Dear Ms. Jensen; Bureau Veritas North America has completed a SECOND review of the following documents on behalf of the City of Tucson: Plans: Two (2) sets of building plans (5sheets, 1 through 5) no dates, no stamps. Structural Calculations: None submitted with this submittal. Truss Calculations: None provided with this submittal. These documents were reviewed only for their conformance to the provisions of the 2003 International Building Codes (i.e., State of Arizona and Tucson amended 2003 IRC, 2003 IMC, 2002 NEC and 2003 IPC). Please submit an itemized response letter and required number of complete and revised documents with all revisions clouded. Sincerely, Bureau Veritas North America Randy McCoy ICC Plans Examiner RMC:sk enclosures Re: Stories: One Occupancy: R-3/VB Building Area (sq. ft.): 1645 (livable) 300 (porch) 1945 Total sq. ft. A. The following plan review comments are based on the City of Tucson Building Regulations and referred to the 2003 International Building Code. B. Please respond in writing to each comment by marking the attached comment list or creating a response letter. Indicate which detail, specification, or calculation shows the requested information. Your complete and clear responses will expedite the re-check and hopefully, approval of this project. Thank you for your assistance. C. These plan review comments are based on building code items only. If site-related comments are applicable to this project, they will be generated by others (e.g., County Engineering, Public Works, Health, etc.). FLOOR PLAN COMMENTS: Show insulation. (R-values). IRC Section N1101.2. ELEVATIONS: Indicate all materials used - stucco, concrete block, glass block, roofing systems, siding, veneers, etc. IRC Section R703. For thin coat stucco systems over foam board, note and specify the ICC Evaluation Report number, system name and manufacturer. Note and specify the vapor barrier used. FOUNDATION PLAN COMMENTS: Provide Note: Footings shall be on undisturbed soil or approved fill IRC Section R403. FRAMING PLAN COMMENTS: Specify design criteria: floor and roof live and dead loads. IRC Section R301. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/25/2007 | GERARDO BONILLA | OUT TO CUSTOMER | Completed |
| 07/25/2007 | GERARDO BONILLA | REJECT SHELF | Completed |