Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T07CM01613
Parcel: 125030850

Address:
2914 E 4TH ST

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T07CM01613
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/13/2007 CLAYTON TREVILLYAN BUILDING-RESIDENTIAL REVIEW Denied PLAN REVIEW COMMENTS
Activity: T07CM01613
Date: 7/16/07

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken.

SCOPE OF REVIEW:
The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2003 International Residential Code, 2003 International Energy Conservation Code, and Arizona State amendments to the 2003 Uniform Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

I. FLOOR PLAN:
[Clarify room designation.]

· The Zoning Department classifies a room of this type as a bedroom. Provide Zoning approval for the proposed area, and appropriate arc-fault protection.

II. FRAMING PLAN:
[Specify header/lintel size and type over hallway at wall/door penetration (keynote #5) through existing wall, Table R502.5.]

· Keynote #5 on floor plan suggests that a portion of the existing wall will be removed. Specify supporting members if the new opening is to be larger than the existing door.

III. DETAILS:
[Specify roof cavity insulation type and size, N1101.2.]

· Provide energy calculations per the 2006 IECC w/ local amendments (climate zone 4B, Pima County <4000 ft, 2100 HDD) to support selected "R" values of insulation, OR specify the simplified prescribed energy values for ceiling R=30 and appropriate rafter depth.
· Provide eave ventilation, and show a minimum 1" ventilation clearance between ceiling insulation and roof sheathing, R806.

If you have any questions please contact:
Clayton Trevillyan
(520) 837-4913
City of Tucson Residential Plan Review

Final Status

Task End Date Reviewer's Name Type of Review Description
07/17/2007 GERARDO BONILLA OUT TO CUSTOMER Completed
07/17/2007 GERARDO BONILLA REJECT SHELF Completed