Permit Number: T07CM01613
Parcel: 125030850

Address:
2914 E 4TH ST

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T07CM01613
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/29/2007 CLAYTON TREVILLYAN BUILDING-RESIDENTIAL REVIEW Denied PLAN REVIEW COMMENTS
Activity: T07CM01613
Date: 7/03/07

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken.

SCOPE OF REVIEW:
The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2003 International Residential Code, 2003 International Energy Conservation Code, and Arizona State amendments to the 2003 Uniform Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

I. FLOOR PLAN pg.A1.0:
· Clarify room designation.
· Code reference R662.10.3(3) for wall sheathing is not applicable.

II. FRAMING PLAN pg.S1.0:
· Specify header/lintel size and type over hallway at wall/door penetration (keynote #5) through existing wall, Table R502.5.
· Provide consistent code year references (2003 or 2006).

III. ELEVATIONS pg.A2.0:
· Note and specify the ICBO evaluation report number, system name and manufacturer with the vapor barrier for thin-coat stucco systems over foam board, R703.6.
· Provide accurate cross-references to section details, R106.1.1.

IV. DETAILS pg.S2.0:
· Specify roof cavity insulation type and size, N1101.2.

V. PLUMBING PLAN pg.P1.0:
· Provide diameter of water line from the meter and water meter size, UPC 610.8.
· Provide keynotes for cross-references of plumbing page.

VI. ELECTRICAL PLAN pg.ME1.0:
· Specify location of smoke detectors, R313.

If you have any questions please contact:
Clayton Trevillyan
(520) 837-4913
City of Tucson Residential Plan Review

Final Status

Task End Date Reviewer's Name Type of Review Description
07/03/2007 DELMA ROBEY APPROVAL SHELF Completed
07/03/2007 DELMA ROBEY OUT TO CUSTOMER Completed
07/03/2007 DELMA ROBEY REJECT SHELF Completed