Permit Number: T07CM01506
Parcel: 140420520

Address:
2320 E ARAGON RD

Review Status: Completed

Review Details: SITE

Permit Number - T07CM01506
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/21/2007 HEATHER THRALL ZONING REVIEW Denied Zoning will be able to approve the site plan once the Engineering and Landscape divisions have approved the site plan. There are no remaining zoning issues at this date.

This review can be done over the counter.
09/25/2007 ANDREW CONNOR LANDSCAPE REVIEW Denied 1. The Environmental Resource Report submitted was reviewed only as it relates to ERZ compliance. Additional comments may apply with subsequent site reviews.

2. The ERR plan prepared shall Including a discernable aerial photograph on the Plant Inventory taken in minimum scale of 1" = 60'. Indicating scale with the following information within the ERR:

3. A description of the maintenance program is required that provides for regular inspections, All mitigation plantings and related improvements shall be maintained for at least three years following installation per DS 2-13.2.5.3

4. Where the Protected Riparian Area is on property that remains under the ownership of a single person or entity following the development, the Protected Riparian Area shall be protected through a conservation or public easement or other legal restriction upon further development per DS 2-13.2.6.D.

5. The site plan must be accompanied by a landscape plan with information specified in development Standard 2-07.0. Show the Protected Riparian Area on the site plan. The landscape plan must be drawn at a standard engineering scale no larger than l" = 60' on a sheet(s) no larger than 30" by 42" (24" by 36" recommended).

6. The site application will be reviewed for compliance only when the approved documents are included in the submittal.

7. This site has outstanding inspections pending Case # T04BU02354 Final Grading, and Landscape inspections have been denied. Include the previously approved landscape plan with re-submittal.

8. Additional comments may apply
09/27/2007 ANDREW CONNOR NPPO REVIEW Denied 1. The Environmental Resource Report submitted was reviewed only as it relates to ERZ compliance. Additional comments may apply with subsequent site reviews.

2. The ERR plan prepared shall Including a discernable aerial photograph on the Plant Inventory taken in minimum scale of 1" = 60'. Indicating scale with the following information within the ERR:

3. A description of the maintenance program is required that provides for regular inspections, All mitigation plantings and related improvements shall be maintained for at least three years following installation per DS 2-13.2.5.3

4. Where the Protected Riparian Area is on property that remains under the ownership of a single person or entity following the development, the Protected Riparian Area shall be protected through a conservation or public easement or other legal restriction upon further development per DS 2-13.2.6.D.

5. The site plan must be accompanied by a landscape plan with information specified in development Standard 2-07.0. Show the Protected Riparian Area on the site plan. The landscape plan must be drawn at a standard engineering scale no larger than l" = 60' on a sheet(s) no larger than 30" by 42" (24" by 36" recommended).

6. The site application will be reviewed for compliance only when the approved documents are included in the submittal.

7. This site has outstanding inspections pending Case # T04BU02354 Final Grading, and Landscape inspections have been denied. Include the previously approved landscape plan with re-submittal.

8. Additional comments may apply
11/06/2007 ELIZABETH EBERBACH ENGINEERING REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
11/07/2007 GERARDO BONILLA OUT TO CUSTOMER Completed