Review Date Reviewer's Name Type of Review Description Status Comments
06/27/2007 PETER MCLAUGHLIN ZONING REVIEW Denied The MS&R plan shows 6th Avenue as a designated major street with a future right-of-way width of 120 feet. Revise the dimension of MS&R right-of-way on the plan on sheet SI-2 and add the MS&R dimensions to sheet SI-3 (Site Plan) as necessary and provide a future site plan and landscape plan showing how the site will meet code in the future when 6th Avenue widening takes place.
DS 2-02.2.1.A.19, LUC 2.8.3.5.F
06/27/2007 PETER MCLAUGHLIN ZONING HC SITE REVIEW Approved
07/09/2007 PATRICIA GILBERT ENGINEERING REVIEW Denied DATE: July 9, 2007
ACTIVITY NUMBER: T07CM01474
PROJECT NAME: Veterans Plaza
PROJECT ADDRESS: 3502 South 6th Avenue
PROJECT REVIEWER: Patricia Gilbert, Engineering Associate

The following items must be revised or added to the site plan. Please include a response letter with the next submittal that states how all comments have been addressed.

RESUBMITTAL REQUIRED: SITE PLAN

SUBMITTAL REQUIRED: DRAINAGE REPORT

1. Provide future sight visibility triangles for the entrance/exit drive to 6th Avenue. The stem side is drawn from the future curb location. DS 2-02.2.1.A.10.

2. Provide existing drainage patterns on sheet SI-2. Include symbol in the legend. DS 2-02.2.1.A.16.

3. Provide finish grades and the finish floor elevation of each structure on sheet SI-2. DS 2-02.2.1.A.16.

4. Provide estimated cut and fill quantities. DS 2-02.2.1.A.17.

5. Per the Major Street and Route Plan 6th Avenue is designated for a future ROW width of 120'. Provide the 60' future ½ ROW dimension. Show the future curb and sidewalk location. For a ROW width of 120' a 9' sidewalk area is required. Revise appropriately. See zoning's comment.

6. If applicable show all easements of record with recordation data on the site plan. DS 2-02.2.1.A.20.

7. Revise the label for the existing ROW dimensions (see comment 5). It appears 6th Avenue is not built out to the future ROW width. There for the label should only read "existing." DS 2-02.2.1.A.21.

8. Provide existing contours and/or spot elevations for the site. Include the Bench Mark based on the City of Tucson datum, include field book and page. DS 2-02.2.1.A.23.

9. This property lies within the boundaries of a "Balanced Drainage Basin," which requires a detention basin facility that ensures a reduction in the existing 2, 10 and 100 year peak discharge from the site. Provide a drainage report addressing the detention requirements for a project within a balanced basin.
07/12/2007 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied 1. A manhole appears to have been added to the private sewer collection system serving the two buildings. Submit the design of the private sewer collection system to the Pima County Department of Environmental Quality for their review. See: http://www.ci.tucson.az.us/dsd/Forms_Fees___Maps/Fees___Instructions/pdeq_flow_chart_A4.pdf for further information.
2. Comment not addressed. Clarify the nature of and the need for the specified 2-way cleanouts shown on drawing SI-11. Reference Sections 103.2.3 and 707.6, UPC 2003.
3. Comment not addressed. Reduced pressure backflow prevention assemblies shall have a diameter at least equal to the diameter of the service connection or the service line at the point of connection. Reference Section 27-76 (b), COT Ordinance 9976, http://www.tucsonaz.gov/water/docs/backflow-ord.pdf
07/12/2007 ANDREW CONNOR LANDSCAPE REVIEW Denied 1. Within a vehicular use area, one (1) canopy tree is required for each 10 motor vehicle parking spaces and every parking space shall be located within forty (40) feet of the trunk of a canopy tree (as measured from the center of the tree trunk) per LUC 3.7.2.3.A.1. Additional tree is required. All plant material must be graphically shown on the landscape plan, note is not sufficient.

2. Plant materials located within SVT's should consist of ground cover or low-growing vegetation of a species that will not grow higher than (30) inches. Revise landscape plan to move all plant material out SVT. Verify that planting plan shows correct spiecies of plants corresponding to landscape plan.

3. Landscape plan shall include irrigation specification design and layout per DS 2-06.5.4.A & DS 2-06.5.4.B including source of irrigation, sleeves for driveways and sidewalks, locations of valves, low-flow bubblers or drip irrigation. Irrigation must be shown grahically on the landscape plan.

4. The site plan and landscape plan must show identical site layout to avoid conflict between the two plans. Ensure that all changes to the site plan are reflected on the landscape plan.

5. Additional comments may apply.
07/12/2007 ANDREW CONNOR NPPO REVIEW Approved Exception

Final Status

Task End Date Reviewer's Name Type of Review Description
07/16/2007 DELMA ROBEY OUT TO CUSTOMER Completed
07/16/2007 DELMA ROBEY REJECT SHELF Completed