Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING/ENGINE/NPPO
Permit Number - T07CM01368
Review Name: RESIDENTIAL BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/11/2007 | DAVE WITT | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T07CM01368 6/18/07 5146 E. 27th STREET PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN. SCOPE OF REVIEW: THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2003 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL. GENERAL REQUIREMENTS: 1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ¼ INCH = 1-FOOT SHALL BE USED FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE. 2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS. 3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES. SITE PLAN: 1. PLEASE NOTE THE SEWER IS REQUIRED TO BE OF A MATERIAL APPROVED FOR USE UNDER BUILDINGS WHERE IT IS UNDER THE NEW PORCH AND 2 FEET OUTSIDE THE PORCH. 4. IS GAS ON THE LOT? PLEASE LOCATE GAS LINE. FOUNDATION PLANS: 1. PLEASE SPECIFY THE WIDTH OF THE FOOTING AROUND THE CLOSET. 2. PROVIDE FOOTINGS ON EACH SIDE OF THE GARAGE DOOR FOR SUPPORT OF THE OHD HEADER. 3. PLEASE PROVIDE DIMENSIONS TO LOCATE THE FOOTING BETWEEN THE GARAGE AND THE MASTER BEDROOM. 4. PLEASE SHOW THE BRACED WALL PANELS ON EACH SIDE OF THE GARAGE OHD. INDICATE THE LENGTHS AND HOLD-DOWNS . SEE R602.10 FLOOR PLANS: 1. PLEASE ELEVATE THE FURNACE AND WATER HEATER TO RAISE THE SOURCES OF IGNITION 18" MINIMUM ABOVE THE FLOOR OF THE GARAGE. SEE M1307.3 2. FLOOR & DEMO PLAN / A-1 ; INDICATE WHICH WINDOW IN (E)BEDROOM #3 IS TO BE INFILLED. STRUCTURAL PLANS: 1. SPECIFY DESIGN CRITERIA ON PLANS. ROOF DEAD LOAD AND LIVE LOAD. 2. PLEASE JUSTIFY THE 2X8 @ 24" OC SPANNING 22' OVER THE GARAGE 3. SPECIFY LUMBER GRADE AND SPECIES. 4. PLEASE EXTEND THE OUTRIGGERS IN TO THE NEXT RAFTER OR JUSTIFY THE SINGLE SPAN MOMENT CONNECTIONS. 5. PLEASE JUSTIFY THE 2X6 @ 24"OC SPANNING 11'-5" OVER THE CLOSET. 6. DETAIL GABLE END BRACING CONNECTIONS. 7. LINTEL SCHEDULE / A-2 ; SMITH PIPE AND STEEL NO LONGER HAS THESE LINTELS. 8. PLEASE PROVIDE A LINTEL FOR THE OPENING BETWEEN THE SITTING ROOM AND THE MASTER BEDROOM. 9. A / A-3 ; PLEASE SHOW THE BEDROOM WALL AND DESCRIBE THE MATERIALS AND CONNECTIONS. SECTIONS - DETAILS - MISC. NOTES: 1. 1,2,3,4 / D-1 ; PLEASE SPECIFY THE MINIMUM EMBEDMENT OF THE ANCHOR BOLTS. SEE R403.1.6 2. PLEASE SPECIFY & JUSTIFY THE R-VALUE OF THE ROOF INSULATION AND THE U-VALUE OF THE WINDOWS. 3. 1 / D-1 ; PLEASE DESCRIBE THE CONTINUOUS STEEL. 4. 1 / D-1 ; HOW DOES THE WOOD IN D-1 COMPLY WITH R319.1 ITEMS 2 & 5. (PLATE, STUDS, AND OSB) 5. 2, 4 / D-1 ; PLEASE SPECIFY THE THICKNESS OF THE STEM WALL. SEE SIMPSON HARDWARE. 6. 6 / D-1 ; SHOULD THE REFERENCE TO THE HOLD-DOWNS ON A-1 BE MADE TO A-2 ? 7. 6 / D-1 ; PLEASE CHECK THE "STH", SHOULD THEY BE "STHD8" ? 8. 6 / D-1 ; PLEASE NOTE, THE "PA' IN THIS APPLICATION, PER SIMPSON, IS EMBEDDED IN THE FOOTING. IF THIS IS OKAY, PLEASE SPEC A LENGTH. HPAHD22 ? 9. 8 / D-1 ; THE "CB" DOESN'T RAISE THE END GRAIN OF THE POST 1" ABOVE THE FLOOR AND REQUIRES A PRESSURE TREATED POST OR A POST OF A WOOD WITH A NATURAL RESISTANCE TO DECAY. CBSQ ? 10. 9 / D-1 ; PLEASE PROVIDE 9-16d NAILS AT THE PLATE SPLICE vs THE 6-16d. SEE TABLE R602.3(1) 11. 1 / D-2 ; PLEASE PROVIDE A COPY OF ICBO REPORT # ER-3899. I COULDN'T FIND IT. 12. 2 / D-2 ; PLEASE EXTEND THE OUTRIGGERS TO THE NEXT TRUSS OR JUSTIFY THE MOMENT CONNECTION. 13. 2 / D-2 ; PROVIDE X-BRACING FOR THE GABLE TRUSS. 14. 4 / D-2 ; ¼" SCREENED VENT HOLES? TYPO ? 15. 4 / D-2 ; PLEASE PROVIDE 3-16d NAILS AT THE RAFTER TO RAFTER CONNECTION. SEE TABLE R602.3(1). PLUMBING PLAN: 1. FIXTURE SCHEDULE / P-1 ; PLEASE SEE TABLES 6-4 AND 7-3 FOR THE CORRECT FIXTURE UNIT COUNT PER FIXTURE. 2. PLEASE CHECK THE WATER DISTRIBUTION SIZE WITH THE NEW F.U. COUNT. MECHANICAL PLANS: 1. PLEASE SIZE THE RETURN AIR DUCT AND THE INITIAL SECTION OF THE SUPPLY DUCT. 2. LOCATE THE A/C CONDENSER (COMPRESSOR). THE EVAPORATOR IS, TRADITIONALLY, OVER THE FURNACE.. PLEASE LOCATE IT ON THE ELECTRICAL PLAN ALSO. ELECTRICAL PLANS: 1. CIRCUIT 2,4 APPEARS TO BE FOR THE EVAPORATOR NOT THE CONDENSER. PLEASE LOCATE THE CONDENSER. 2. PLEASE RE-CHECK THE MATH FOR THE PERCENTAGE OF AN ACRE, 95' X 76' / 43560 = 16.5 % 3. PLEASE PROVIDE TWO COPIES OF THE CUT SHEET FOR THE PROPOSED LIGHTING FIXTURE. THE KICHLER #9023 FIXTURE'S OUTPUT DIFFERS FROM YOUR NUMBERS. ARE ALL 3 LIGHTING FIXTURES GOING TO BE THE SAME KICHLER FIXTURE? IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: DAVE WITT @ 837-4910 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/06/2007 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
| 07/06/2007 | CINDY AGUILAR | REJECT SHELF | Completed |