Permit Number: T07CM01310
Parcel: 133070450

Review Status: Completed

Review Details: RESIDENTIAL BLDG/ZONING-WALKTHRU

Permit Number - T07CM01310
Review Name: RESIDENTIAL BLDG/ZONING-WALKTHRU
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/22/2008 MICHAEL ST. PAUL ZONING REVIEW Approved CDRC TRANSMITTAL


FROM: Michael St.Paul, Planning Technician

PROJECT:
T07CM01310
8601 East Wrightstown Road
Carport and covered patio additions


TRANSMITTAL: January 18, 2008


COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. (We should be able to address all the following plot plan comments on the counter. Please provide the following information and corrections on the plot plan.)


1) This review is for remodel of and additions to a single-family residence (SFR). The zoning is RX-2 (LUC Section 2.3.3.2.A.1). The Development Designator is "F" (LUC Section 3.2.3.1.A). The Perimeter Yard Indicator is BB (LUC Section 3.2.6.4). This site is located along East Wrightstown Road, which is on the Major Streets and Routs (MS&R) plan (LUC Section 2.8.3).

2) The minimum lot size is 16,000 square feet. Please provide the square footage of the lot on the plot plan (LUC Section 3.2.3.1.A).

3) The minimum setback for the back and side yards along the interior lot lines (not along the streets) is twenty (20'-0" LUC Section 3.2.3.A). The setbacks are incorrectly identified on the plot plan. Please delineate these setbacks with dimensions on the plot plan.

4) The minimum side yard setback along a street for any property adjacent to a street on the MS&R plan is the greater of twenty-one feet (21'-0") or the height measured from the edge of the travel lane (LUC Sections 3.2.6.5. & 2.8.3.6).

5) For any lot with frontage along a MS&R there must be a vehicle use turn around area so that it is not necessary for vehicles to back out into the MS&R (LUC Section 3.2.3.14.3).

6) The minimum length of a driveway measured from the front of a carport or a garage is eighteen feet (18'-0") to the property line (LUC Section 3.2.6.5.B.2.a).

7) Provide a copy of the last stamped approved plot plan. (There should be one in records. The carport was enclosed to a garage in 1982.)

8) Provide a copy of the floor plan with the purposed additions.
01/22/2008 PAUL MACHADO ENGINEERING REVIEW Approved
05/30/2008 PMACHAD2 NPPO REVIEW Passed
05/30/2008 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Approved