Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T07CM01263
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/30/2007 | SREEVES1 | 2ND PARTY REVIEW | REVIEW | Denied | April 30, 2007 City of Tucson Development Services P.O. Box 27210 Tucson, AZ 85726 RE: Reeves Residence Addition – 1ST REVIEW CITY OF TUCSON LOG NO. T07CM01263 WILLDAN PROJECT NO. 13881-7046 The initial review for the above project has been completed. This letter contains comments which need to be addressed by written responses to each which indicate any actions taken. In order to facilitate a shorter second review, all corrections and revisions must be made on the original plans and two complete new sets of prints, along with one complete redlined set, must be returned to our office. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets, and that all changes have been highlighted with appropriate revision numbers, revision dates, and “cloud bubbles.” Pen or pencil corrections on final prints are not acceptable. This project has been reviewed for conformance with the 2003 IRC, 1997 UAC, and the 2003 UPC. Any revisions to this plan will require an additional review and approval by Willdan. Should you have questions regarding the comments herein, please contact your plans examiner Chris Kiel. Occupancy Occup. Load Construction Area S.F. Sprinklered Alarms SFR N/A V-B 280 No Smoke ARCHITECTURAL COMMENTS: Sheet 2 Provide complete drawings of all elevations. Show building heights. Reference IRC Section R106.1.1. Indicate all materials used; stucco, roofing system, etc. Reference IRC Section R703.1. Sheet 3 For thin-coat stucco systems over foam board, note and specify the listing agency’s evaluation report number, system name and manufacturer, and note and specify the vapor barrier. Reference IRC Section 106.1. Show calculation of attic ventilation area. Note location of all vents needed to comply or show compliance with an accepted Non-vented Roof Method Details 1-8, Dated 7/18-19/2001 as permitted by Section R104.11, Alternate Methods. Reference IRC Section R806.2. Annotate on the plans that the weep screed will be a minimum of 4” above the earth and a minimum of 2” above paved surfaces. Reference IRC Section R703.6.2.1. This section detail seems to be the detail shown on Sheet #4. Please clarify. Reference 2003 IRC Section 106.1.1. STRUCTURAL COMMENTS: Sheet 3 Locate and identify brace wall types and locations, along with the appropriate nailing schedule. Reference IRC Section R106.1.1. Specify design criteria on plans. Provide values for floor dead load and live load, as well as roof dead load and live load. Reference IRC Sections R301.4 and R301.5. Specify lumber grade and species. Specify manufacturer and series on glue-lams and “I” joists. Reference IRC Section R106.1.1. PLUMBING COMMENTS: Sheet 4 Show the size of all waste lines, vents, and required clean-outs. Reference City of Tucson Submittal Requirements. Waterline: Provide the total fixture unit demand (based on Tables 6-4 & 7-3 or Tables L-1 & L-2) and the maximum developed length. Reference UPC Section 610. The City of Tucson has adopted the 2003 Uniform Plumbing Code with local amendments. All plans must reference the 2003 UPC with local amendments in its entirety. MECHANICAL COMMENTS: Sheet 4 Show exhaust fan locations and exhaust duct terminations for bathrooms, water closet compartments and similar rooms in lieu of operable windows. Reference IRC Section R303.3. Please show how heating will be provided for the new bedroom to maintain 68° at a minimum height of 3’ from the floor. Reference 2003 IRC Section 303.8. ELECTRICAL COMMENTS: Sheet 4 Designate on the plans the location and circuit of all required light fixtures, receptacles, and switches. Provide a panel schedule noting circuit number and size along with a general description. Reference IRC Chapters E38, E39 and City of Tucson Submittal Requirements. Submit panel schedule showing circuit amps, wire size, panel size, and circuit numbers. Reference IRC Section 3502.2 and City of Tucson Submittal Requirements. When ceiling finish materials are removed, existing bedrooms shall be in compliance. When ceiling finish materials are not removed, existing bedrooms shall be equipped with battery operated smoke detectors. Reference IRC Sections R313.1 and R313.1.1. ENERGY CODE COMMENTS: Sheet 2 Indicate on the plan the “R” values of insulation, as well as the “U” values of the windows, skylights, and doors in compliance with the energy calculations provided or prescriptive requirements of Chapter 11. Reference IRC Section R106.1.1. Please submit the required energy code calculations by using the “RES” check program, Chapter 11 of the IRC, or the 2003 IECC, and also annotate on the plans. Reference IRC Section R106.1.1. Sincerely, WILLDAN Chris Kiel, C.B.O., M.C.P. Building Official CEK/jk |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 05/07/2007 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 05/07/2007 | SUE REEVES | REJECT SHELF | Completed |