Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - SITE ALL
Permit Number - T07CM01128
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/16/2007 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 08/20/2007 | STEVE SHIELDS | ZONING HC SITE | REVIEW | Approved | |
| 08/20/2007 | STEVE SHIELDS | ZONING | REVIEW | Denied | DSD TRANSMITTAL FROM: Steve Shields Lead Planner PROJECT: Pockets Pool & Pub - 1062 S. Wilmot Road T07CM01128 Site Plan (4th Review) TRANSMITTAL DATE: August 20, 2007 COMMENTS: Please resubmit revised drawings and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. This site plan was reviewed for compliance with the City of Tucson Development Standards (D.S.) and Land Use Code (LUC). Based on the expansion calculation provided, code compliance for the expansion only is required. 2. D.S. 3-05.2.2.D A minimum distance of three (3) feet will be provided between the back of spur and any wall, screen, or other obstruction over six (6) inches in height. There does not appear to be three (3) feet from the curbing shown at the end of the PAAL, northwest corner of parking area, to the existing chain link fence. 3. If the proposed curbing shown at along the west end of the parking is to be used as the wheel stop then a minimum distance of two and one half (2 ½) feet must be maintained between the front of the parking space and the fence, D.S. 3-05.2.3.C.1 & .2. Show and dimension the overhang area or provide wheel stops. 4. Per D.S. 2-08.4.1.C provide a four (4) foot sidewalk between the west side of the building and the proposed parking spaces. This sidewalk is must connect to the existing pedestrian circulation on site. 5. Some type of barrier (curbing, post barricades, wheel stops) is required between the parking space, located near the southeast corner of the building, and the landscape area, D.S. 3-05.2.3.C.1. Also there appears to be new curbing along the east end of the handicapped parking space, clarify. 6. Zoning acknowledges that the parking calculation appears to be correct. Remove the reference to "EXCLUDING KITCHEN 994 S.F." from the parking calculation. 7. Additional comments may be forth coming depending on how each comment has been addressed. 8. Zoning will provide an over the counter review once the above comments have been addressed. Call or email to schedule an appointment. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956. C:\planning\site\t07cm01128-4th.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents |
| 08/23/2007 | ANDREW CONNOR | NPPO | REVIEW | Approved | |
| 08/23/2007 | ANDREW CONNOR | LANDSCAPE | REVIEW | Approv-Cond | |
| 09/11/2007 | PATRICIA GILBERT | ENGINEERING | REVIEW | Denied | DATE: September 11, 2007 ACTIVITY NUMBER: T07CM01128 PROJECT NAME: Pockets Pool and Pub PROJECT ADDRESS: 1062 South Wilmot Road PROJECT REVIEWER: Patricia Gilbert, Engineering Associate The following items must be revised or added to the site plan. Please include a response letter with the next submittal that states how all comments have been addressed. RESUBMITTAL REQUIRED: SITE PLAN 1. A sidewalk will be provided adjacent to any parking space accessed by a PAAL where the space is located on the same side of the PAAL as any building and no other parking spaces or PAALs intervene. Provide a 4' sidewalk along the west side of the building. DS 2-08.4.1.C. 2. A minimum distance of three (3) feet will be provided between the back of spur and any wall, screen, or other obstruction over six (6) inches in height. There does not appear to be three (3) feet from the curbing shown at the end of the PAAL to the existing chain link fence. D.S. 3-05.2.2.D 3. Provide a barrier between the parking space and the landscape area located adjacent to the south east corner of the building. DS 3-05.2.3.C.1. |
| 09/14/2007 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 09/14/2007 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
| 09/14/2007 | CINDY AGUILAR | REJECT SHELF | Completed |