Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING/ENGINE/NPPO
Permit Number - T07CM01063
Review Name: RESIDENTIAL BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
04/18/2007 | ANDREW CONNOR | NPPO | REVIEW | Approved | Submit NPPO plan or Application for Exception; include acceptable documentation, which clearly indicates that the project will not impact Protected Native Plants |
04/25/2007 | LINHART PETERSEN POWERS ASSOC | BUILDING-RESIDENTIAL | REVIEW | Denied | April 25, 2007 CITY OF TUCSON- FIRST CHECK Tucson Appl. No. T07CM01063 Bureau Veritas Job No. 01007-161001.037 Transform Building System 6250 S. Del Moral Tucson AZ 85706 Re: Plan Review: Monterey Addition SFR Address: 1740 N. Mountain Ave. Bureau Veritas North America has completed a First review of the following documents on behalf of the City of Tucson: DOCUMENTS/ENCLOSURES: (NO RESPONSE REQUIRED FOR THIS SECTION) Plans: Two (2) sets of plans (6 sheets, 1 through P1) no stamps or dates. Truss Calculations: None provided with this submittal. Structural Calculations: None provided with this submittal. 4. Energy Compliance: None provided with this submittal These documents were reviewed only for their conformance to the provisions of the 2003 International Building Codes (i.e., State of Arizona and Pima County amended 2003 IRC, 2003 IMC, 2002 NEC and 2003 IPC). Our comments follow on the attached list. Please submit an itemized response letter and required number of complete and revised documents with all revisions clouded. Sincerely; Bureau Veritas Shelley K. Knuffke ICC Plans Examiner SK;skThese documents were reviewed only for their conformance to the provisions of the 2003 International Building Codes, 2003 International Residential codes, (i.e., State of Arizona and Pima County amended 2003 IRC, 2003 IMC, 2002 NEC and 2003 IPC). Please respond in writing to each comment by marking the attached comment list or creating a response letter. Indicate which detail, specification, or calculation shows the requested information. Your complete and clear responses will expedite the re-check and hopefully, approval of this project. Thank you for your assistance. These plan review comments are based on building code items only. If site-related comments are applicable to this project, they will be generated by others (e.g., City Engineering, Public Works, Health, etc.). STRUCTURAL COMMENTS: Note and specify all roof slopes. IRC Chapter 9. Illustrate required holddowns on foundation plan as specified on lateral design or as required for all alternate braced wall panels. Provide attic ventilation calcs. For all concealed attic spaces; include required and provided net free ventilation area. Also, indicate the type and location of attic ventilation. Provide the following note if applicable. “Where eave or cornice vents are installed insulation shall not block the free flow of air. A minimum of 1 inch space shall be provided between the insulation and roof sheathing at the location of the vent”. IRC Section R806. Provide note: Footings shall be on undisturbed soil or approved fill. IRC Section R403. Foundation plates and sills shall be bolted to the foundation with minimum ½ inch bolts at 6 ft. or less on center, and embedded a minimum 7 inches into the foundation. IRC Section R403.1.6. Specify design criteria: floor and roof live and dead loads. IRC Section R301 Show all required blocking. IRC Section R602.8. BUILDING CROSS -SECTION COMMENTS: Provide building cross-sections. Cross-sections shall be referenced to the floor plan and structural plans. ELEVATIONS COMMENTS: Provide complete drawings of all elevations. Include patio covers, decks, fireplaces and bay windows. IRC Section 106 Indicate all material used-stucco, concrete block. Glass block, roofing systems, siding, veneers, etc. IRC Section R703. Provide height dimensions for roof line, headers, top plate and finished floor. IRC Section R106. For thin coat stucco systems over foam board, note and specify the ICBO Evaluation Report number, system name and manufacturer. Note and specify the vapor barrier used. MECHANICAL COMMENTS: Provide a complete mechanical plan. Designate the locations, capacity and fuel type (electric or gas) of the heating and air conditioning equipment. Designate the locations, dimensions and CFM of each air supply register, return air grill and all ductwork. IRC Section R106.1. The dwelling unit shall be provided with heating facilities capable of maintaining a room temperature of 68 degrees at a point three feet above the floor and 2 feet from exterior walls in all habitable rooms. IRC Section R 303.6 Clarify A/H #1 on plans. Is this a heater? Provide manufacture’s specs and installation instructions. Show that all ducts meet the minimum requirements of IRC Section M1602 for return air and M1603 for supply air. Provide combustion air for all liquid and solid-fuel burning appliances including size, type and location of openings. IRC Chapter 17. The clothes dryer exhaust duct shall be at least the diameter of the appliance outlet and shall terminate on the outside of the building. It shall not exceed 25 feet in length with reductions for bends. The duct shall terminate not less than 3 feet form the property line. IRC Sections M1501 and R302.2. Show condensate line and secondary condensate line. IRC Section M1411.3 and M1411.3.1. PLUMBING COMMENTS: Provide gas isometric with length of line (horizontal and vertical) to each appliance, BTU demand for each appliance, size of each branch, total demand and size of meter. Specify materials for waste, water and gas pipes. ELECTRICAL COMMENTS: Provide note: Smoke alarms shall receive their primary power from the building wiring with battery backup. Wiring shall be permanent without a disconnecting switch other than those required for overcurrent protection. IRC Section R317.2. Provide bonding to the interior water piping and above ground portion of gas piping systems. IRC Section E3509.6. END OF REVIEW COMMENTS Should you have any inquiries regarding this letter, contact Bureau Veritas N.A., Shelley K Knuffke at (520) 576-8400 or fax no. (520) 622-2110 Monday – Friday 8 AM to 5 PM. Shelley K. Knuffke ICC Plans Examiner/Building Inspector |
04/26/2007 | PATRICIA GILBERT | ENGINEERING | REVIEW | Approved | |
05/11/2007 | TERRY STEVENS | ZONING | REVIEW | Approved |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
05/15/2007 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
05/15/2007 | CINDY AGUILAR | REJECT SHELF | Completed |