Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T07CM01062
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/19/2007 | SREEVES1 | 2ND PARTY REVIEW | REVIEW | Denied | July 19, 2007 City of Tucson Development Services 201 N. Stone Avenue Tucson, AZ 85701 RE: BARRENTINE RESIDENCE ADDITION – 2nd REVIEW CITY OF TUCSON LOG NO. T07CM01062 WILLDAN PROJECT NO. 13881-7054 The second review for the above project has been completed. This letter contains comments which need to be addressed by written responses to each which indicate any actions taken. In order to facilitate a shorter second review, all corrections and revisions must be made on the original plans and two complete new sets of prints, along with one complete redlined set, must be returned to our office. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets, and that all changes have been highlighted with appropriate revision numbers, revision dates, and “cloud bubbles.” Pen or pencil corrections on final prints are not acceptable. This project has been reviewed for conformance with the 2003 IRC, 1997 UAC, 2003 IMC, 2003 IECC, 2002 NEC codes with local modifications, and the 2003 UPC with State of Arizona Amendments. Any revisions to this plan will require an additional review and approval by Willdan. Should you have questions regarding the comments herein, please contact your plans examiner Chris Kiel. Occupancy Occup. Load Construction Area S.F. Sprinklered Alarms Dwelling Garage Patio N/A V-B 930 715 188 No Smoke ARCHITECTURAL COMMENTS: Reviewed and accepted. STRUCTURAL COMMENTS: Reviewed and accepted. PLUMBING COMMENTS: Sheet 10 Show the size of all waste lines, vents, and required clean-outs. Reference City of Tucson Submittal Requirements. Comment remains: Please show the size of all required clean-outs. Waterline: Provide the total fixture unit demand (based on Tables 6-4 or Tables L-1 & L-2) and the maximum developed length. Reference the 2003 UPC Section 610. Comment remains: Not addressed. The City of Tucson has adopted the 2003 Uniform Plumbing Code with local amendments. All plans must reference the 2003 UPC with local amendments in its entirety. Comment remains: Not addressed. MECHANICAL COMMENTS: Sheet 9 Show exhaust fan locations and exhaust duct terminations for bathrooms, water closet compartments and similar rooms in lieu of operable windows. Reference IRC Section R303.3. Comment remains: Not addressed. ELECTRICAL COMMENTS: Sheet 11 Where ceiling fans are shown on the plans, provide a note indicating only approved outlet boxes shall be used. Reference IRC Section E4001.6. Comment remains: Not addressed. Note that light fixtures in clothes closets shall be installed in accordance with IRC Section E3903.11. Comment remains: Not addressed. Please provide cut sheets for all the exterior light fixtures shown or noted on plans. The cut sheets need to provide lumens per fixture and show if the fixture is a full cut-off, which means no light is emitted at or above the horizontal plane. Please provide cut sheets and calculations for all exterior lighting fixtures, including existing. Reference City of Tucson Outdoor Lighting Code. Comment remains: The fixture provided is not a shielded fixture. Cross-reference exterior lighting fixtures on the plans with the cut sheets and calculations submitted. Reference City of Tucson Submittal Requirements. Comment remains: The lumens proved are over the maximum allowable limit. ENERGY CODE COMMENTS: Sheet 4 Please submit the required energy code calculations by using the “RES” check program, Chapter 11 of the IRC, or the 2003 IECC, and also annotate on the plans. Reference IRC Section R106.1.1. Comment remains: Not addressed. Sincerely, WILLDAN Chris Kiel, C.B.O., M.C.P. Building Official CEK/cc |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/20/2007 | THAUSER1 | OUT TO CUSTOMER | Completed |
| 07/20/2007 | THAUSER1 | REJECT SHELF | Completed |