Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T07CM00885
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/28/2007 | BROWN & ASSOCIATES | 2ND PARTY REVIEW | REVIEW | Denied | June 27, 2007 Angel Gallando 1053 W. Michigan St. Tucson, AZ 85714 RE: GALLARDO RESIDENCE, ADDITION ADDRESS: 1053 W. MICHIGAN STREET CITY OF TUCSON LOG NO.: T07CM00885 BROWN & ASSOCIATES PLAN CHECK NO: 85701-7009 The first review comments in this letter require that the applicant respond with a detailed written response to each comment indicating actions taken to resolve the comment issue. We request that you provide reviewed and coordinated construction documents as applicable, highlighting each change with a clouded or delta and a revision number on each drawing revised. Third and subsequent reviews are charged additionally at the current hourly rate for administration and plans examinations. Occupancy Occupant Load Construction Area Sq. Ft. Sprinklered Alarms R-3 N/A V-B 812 No Smoke Detector Special Inspection Certificate Provided Required Type No No Deferred Submittals Required Type No No PLAN REVIEW COMMENTS Sheet ST1 1. Indicate on the site plan the new sewer connections to the laundry and half bath. Indicate depth of existing sewer and slope of new pipe. Provide additional clean-outs where needed. Reference IRC Section P3005. Sheet A.2 1. A slab is shown at the rear of the addition. A patio is indicated on this sheet. Coordinate plans to reflect the actual project. Is the existing patio being incorporated into the new addition? Please clarify. Reference IRC Section 106. Gallardo Residence, Addition City of Tucson Log No.: T07CM00885 June 28, 2007 Page 2 2. Specify if key notes refer to Sheet A 2.1. Reference IRC Section 106. Sheet A2.1 1. Specify size and type of windows. Light and ventilation requirements of IRC Chapter 303 must be met. 2. Label all rooms and spaces. If the room off of the Family Room is to be a half-bath, show all fixtures in that space. Notes on P1 indicate a sink in the new Laundry- show this on the plan. Reference IRC Section 106. Sheet A.3 1. Please note if existing patio is being removed. Provide dimensions to the footing located in the interior of the slab. Reference IRC Section 106. 2. Verify with sections and details the reinforcing of all footings and turn-downs. Reference IRC Section 403.1.3.2. 3. Provide dowels to tie the new slab into the existing in order to prevent settling. Reference IRC Section 403.1.8. Sheet A.5 1. Provide a weep screed at the base of the stucco system to prevent moisture build-up under the stucco. The weep screed must be located at least 2” above any paved (slab) areas. Reference IRC Section 703.6.2.1 2. Attach ceiling rafters with approved metal connectors. Sheet E.1 1. A light must be provided at each habitable room. Reference IRC Section E3803. 2. Ground Fault outlets must be provided in laundry, bath and exterior locations. Reference IRC Section E3802. 3. Provide a switched light and an outlet at the rear of the house. Reference IRC Section E3801.7. 4. Show all outlets for all appliances- washer/ dryer. Reference IRC Section 106. 5. Indicate the location of the existing water heater. Reference IRC Section 106. Sheet E.2 1. Update the load calculation. Reference IRC Section E 3604.3(1). Gallardo Residence, Addition City of Tucson Log No.: T07CM00885 June 28, 2007 Page 3 Sheet P.1 1. Label all plumbing components or appliances. Show all built in fixtures. Reference IRC Section 106. Sheet P.2 1. Provide a complete waste diagram of the new fixtures. Clearly indicate the sewer line run, size, vent sizing, etc. Reference IRC Section 106. Brown & Associates contact information: If you have any questions regarding resubmittal requirements or procedures please contact Patti Schechter, Operations Manager at 480 991-3751. If you have any questions or require additional clarification regarding these comments please contact Mary Dickson, Plans Examiner at 480 991-3751. Sincerely, BROWN & ASSOCIATES for CITY OF TUCSON Michael J. Brown, C.B.O. President MB:ps TU 7009.1st Rev |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/10/2007 | GERARDO BONILLA | OUT TO CUSTOMER | Completed |
| 07/10/2007 | GERARDO BONILLA | REJECT SHELF | Completed |