Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T07CM00819
Review Name: COMMERCIAL TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/05/2007 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 03/14/2007 | WILLDAN | ADA | REVIEW | Denied | City of Tucson Development Services P.O. Box 27210 Tucson, AZ 85726 RE: Temple of Music & Art ADA Modifications CITY OF TUCSON LOG NO. T07CM00819 WILLDAN PROJECT NO. 13881-7034 – 1ST REVIEW The initial review for the above project has been completed. This letter contains comments which need to be addressed by written responses to each which indicate any actions taken. In order to facilitate a shorter second review, all corrections and revisions must be made on the original plans and two complete new sets of prints, along with one complete redlined set, must be returned to our office. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets, and that all changes have been highlighted with appropriate revision numbers, revision dates, and “cloud bubbles.” Pen or pencil corrections on final prints are not acceptable. This project has been reviewed for conformance with the 2003 IBC, 1997 UAC, 2003 IMC, 2003 IECC, 2002 NEC, and the 2003 UPC. Any revisions to this plan will require an additional review and approval by Willdan. Should you have questions regarding the comments herein, please contact your plans examiner Jim Singleton. Occupancy Occup. Load Construction Area S.F. Sprinklered Alarms A-1/A-3/B/M No Change II-B-AS 26,104 Yes Yes Special Inspection is required for the following items: N/A The following items are acceptable for deferred submittals: N/A GENERAL COMMENTS: General The plans have been reviewed to the 2003 ICC/ANSI 117.1, 2003 IBC Chapter 11 and January 1998 ADDAG Accessibility Guidelines. ARCHITECTURAL COMMENTS: Sheets A2.1 and A3.1 The 2 doors in series do not provide the required space between the doors. The minimum required space is 48”, plus the width of the door’s encroachment into the space. Thus, a minimum of 48” + 36” is required for this configuration. If the outer door is swung out, this problem is eliminated. Reference 2003 ICC/ANSI 117.1, Figure 404.2.5 (c), and 1998 ADDAG Section 4.13.7. STRUCTURAL COMMENTS: Reviewed and accepted. PLUMBING COMMENTS: Reviewed and accepted. MECHANICAL COMMENTS: Not part of this review. ELECTRICAL COMMENTS: Reviewed and accepted. ENERGY CODE COMMENTS: There does not appear to be any modifications to the building envelope or systems that triggers the IECC Chapter 1. ACCESSIBILITY COMMENTS: See the Architectural comments on Sheets A2.1 & A3.1 and revise the plans to resolve the discrepancies. Reference 2003 ICC/ANSI 117.1, Fig. 404.2.5 (c) and 1998 ADDAG Section 4.13.7. Sincerely, WILLDAN Martin Haeberle, C.B.O. Building Official MAH/tb |
| 03/14/2007 | WILDAN | 2ND PARTY REVIEW | REVIEW | Denied | City of Tucson Development Services P.O. Box 27210 Tucson, AZ 85726 RE: Temple of Music & Art ADA Modifications CITY OF TUCSON LOG NO. T07CM00819 WILLDAN PROJECT NO. 13881-7034 – 1ST REVIEW The initial review for the above project has been completed. This letter contains comments which need to be addressed by written responses to each which indicate any actions taken. In order to facilitate a shorter second review, all corrections and revisions must be made on the original plans and two complete new sets of prints, along with one complete redlined set, must be returned to our office. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets, and that all changes have been highlighted with appropriate revision numbers, revision dates, and “cloud bubbles.” Pen or pencil corrections on final prints are not acceptable. This project has been reviewed for conformance with the 2003 IBC, 1997 UAC, 2003 IMC, 2003 IECC, 2002 NEC, and the 2003 UPC. Any revisions to this plan will require an additional review and approval by Willdan. Should you have questions regarding the comments herein, please contact your plans examiner Jim Singleton. Occupancy Occup. Load Construction Area S.F. Sprinklered Alarms A-1/A-3/B/M No Change II-B-AS 26,104 Yes Yes Special Inspection is required for the following items: N/A The following items are acceptable for deferred submittals: N/A GENERAL COMMENTS: General The plans have been reviewed to the 2003 ICC/ANSI 117.1, 2003 IBC Chapter 11 and January 1998 ADDAG Accessibility Guidelines. ARCHITECTURAL COMMENTS: Sheets A2.1 and A3.1 The 2 doors in series do not provide the required space between the doors. The minimum required space is 48”, plus the width of the door’s encroachment into the space. Thus, a minimum of 48” + 36” is required for this configuration. If the outer door is swung out, this problem is eliminated. Reference 2003 ICC/ANSI 117.1, Figure 404.2.5 (c), and 1998 ADDAG Section 4.13.7. STRUCTURAL COMMENTS: Reviewed and accepted. PLUMBING COMMENTS: Reviewed and accepted. MECHANICAL COMMENTS: Not part of this review. ELECTRICAL COMMENTS: Reviewed and accepted. ENERGY CODE COMMENTS: There does not appear to be any modifications to the building envelope or systems that triggers the IECC Chapter 1. ACCESSIBILITY COMMENTS: See the Architectural comments on Sheets A2.1 & A3.1 and revise the plans to resolve the discrepancies. Reference 2003 ICC/ANSI 117.1, Fig. 404.2.5 (c) and 1998 ADDAG Section 4.13.7. Sincerely, WILLDAN Martin Haeberle, C.B.O. Building Official MAH/tb |
| 03/15/2007 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 03/15/2007 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 03/16/2007 | SUE REEVES | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 03/24/2007 | PATRICIA GILBERT | ENGINEERING | REVIEW | Approved | |
| 04/05/2007 | DAVID RIVERA | ZONING | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 04/11/2007 | FSANCHE1 | OUT TO CUSTOMER | Completed |
| 04/11/2007 | SUE REEVES | REJECT SHELF | Completed |